枕头坝一级水电站调速器压油装置压力油罐进油管路振动较大问题分析及处理  

Analysis and Treatment of Excessive Vibration of the Pressure Tank Inflow Pipeline in the Oil Pressure Device in Zhentouba Ⅰ Hydropower Station

在线阅读下载全文

作  者:何兆品 唐义超 HE Zhaopin;TANG Yichao(Dadu River Maintenance and Installation Co.,Ltd.,China Energy Investment Corporation,Leshan 614900,China)

机构地区:[1]国家能源集团大渡河检修安装有限公司,四川乐山614900

出  处:《水电与新能源》2019年第2期59-60,共2页Hydropower and New Energy

摘  要:枕头坝一级水电站水轮机调速器压油装置压油泵在停泵过程中,存在压力油罐进油管路振动较大的问题,对其原因进行了深入分析研判,经对压油装置控制逻辑程序修改,压油泵启停试验中压力油罐进油管路剧烈振动情况消失,彻底根除了设备运行过程中的隐患,保障了设备安全稳定运行。During the shutdown process of the oil pump in the oil pressure device in Zhentouba Ⅰ Hydropower Station, excessive vibration is observed in the pressure tank inflow pipeline. Analysis shows that this problem is caused by the water hammer effect of the pressure oil, which is induced by improper control logic sequence of the shutdown process. Thus, the control logic sequence of the oil pressure device is revised. After the treatment, the abnormal vibration problem is successfully solved. The safety and stability of the device is improved.

关 键 词:调速器 压油装置油泵 电液隔离阀 振动 

分 类 号:TV734.4[水利工程—水利水电工程]

 