检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:官贞珍 朱全军 樊习英 曹枚根[4] 袁斌霞 王昊 GUAN Zhenzhen;ZHU Quanjun;FAN Xiying;CAO Meigen;YUAN Binxia;WANG Hao(College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 200090, China;Institute of New Electrical Materials, Global Energy Interconnection Research Institute, Beijing 102211, China;State Grid Shanxi Economic Research Institute, Taiyuan, 030001,China;China Electric Power Research Institute, Beijing 100055, China)
机构地区:[1]上海电力学院能源与机械工程学院,上海200090 [2]全球能源互联网研究院,北京102211 [3]国网山西省电力公司经济技术研究院,山西太原030001 [4]中国电力科学研究院,北京100055
出 处:《地震工程与工程振动》2018年第3期184-193,共10页Earthquake Engineering and Engineering Dynamics
基 金:国家电网科技项目(SGRI-WD-71-15-010)~~
摘 要:重点介绍美国IEEE Std 693-2005、IEC系列标准和我国电气设备抗震规范的基本情况后,从抗震设防目标、设防水准、场地类别、抗震设计反应谱、安装方式、抗震措施和抗震能力要求等方面对比分析了电气设备抗震设计技术的差异,指出我国规范中设计的不足。通过对比研究美欧先进的电气设备抗震设防标准,提出了改进我国电气设备抗震设计规范修订的建议。建议我国应适度提高电气设备抗震设防目标和设防水准、重新考虑阶梯跳跃变化的场地分类方案,修正设计反应谱的特征周期和反应谱值,以及提高我国电气设施抗震设计的措施等,提高我国电气设备的抗震能力。It was put emphasis on introducing the basic information of IEEE Std 693-2005 of USA,IEC standard and China’s code for seismic design of electrical installations,and comparing the difference of seismic design technologies of electrical equipment in aspects of precautionary objectives,seismic qualification levels,site class definitions,the required response spectrum,mounting,seismic measures and seismic qualification among the above three standards,and it pointed out the shortcomings in seismic design in our country. Through comparative study on the advanced seismic precautionary standards for electrical equipment of USA and Europe,this paper put forward some suggestions on our country’s seismic design improvement and standard revision. It was suggested that China should improve the seismic precautionary objectives and seismic qualification levels of electrical equipment,reconsider the site classification scheme of terraced jump variations,modify the design characteristic periods of ground motion and response spectrum values of design response spectra,and improve the measures of seismic design of electrical installations to improve the seismic capability of electrical equipment in our country.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.44