某电站锅炉前屏过热器爆管原因分析  被引量:5

Cause Analysis of the Tube Burst of the Front Screen Superheater of the Boiler in a Power Station

在线阅读下载全文

作  者:郭可伟[1] 马春江[1] 丁勇能[1] GUO Kewei;MA Chunjiang;DING Yongneng(Hangzhou Huadian Banshan Power Generation Co.,Ltd.,Hangzhou Zhejiang 310015,P.R.China)

机构地区:[1]杭州华电半山发电有限公司,浙江杭州310015

出  处:《重庆电力高等专科学校学报》2019年第1期16-20,43,共6页Journal of Chongqing Electric Power College

摘  要:通过对锅炉前屏过热器爆管管段进行宏观检测和金相、力学性能分析,结合锅炉的实际运行参数,找出造成前屏过热器爆管的原因,制订切实可行的措施,从而减少锅炉受热面管的爆管次数,提高机组运行的安全性与经济性。Based on the macro-detection,metallographic analysis and mechanical property analysis of the tube burst section of the front screen superheater of the boiler,in combination with the operating parameters of the boiler,this paper analyzes the causes of the tube burst and introduces feasible measures to reduce the occurrences of the tube burst of the heating surface tube as well as enhancing the security and economy of the operation of the unit.

关 键 词:锅炉 前屏过热器 爆管 原因分析 

分 类 号:TM621.2[电气工程—电力系统及自动化]

 