Performances of different efficiency calibration methods of high-purity-germanium gamma-ray spectrometry in an inter-comparison exercise  被引量:7

Performances of different efficiency calibration methods of high-purity-germanium gamma-ray spectrometry in an inter-comparison exercise

在线阅读下载全文

作  者:Bao-Lu Yang Qiang Zhou Jing Zhang Shuai-Mo Yao Ze-Shu Li Wen-Hong Li Fei Tuo 

机构地区:[1]Key Laboratory of Radiological Protection and Nuclear Emergency, National Institute for Radiological Protection,Chinese Center for Disease Control and Prevention

出  处:《Nuclear Science and Techniques》2019年第3期9-14,共6页核技术(英文)

基  金:supported by the Support Program of the Ministry of Science and Technology(No.2014FY211000);the National Key Technology Research and Development Program(No.2013BAK03B05)

摘  要:This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in an inter-comparison exercise. Although the results of LabSOCS and ANGLE for ^(241)Am emitting lowenergy gamma rays were not very satisfactory, all of the three efficiency calibration methods passed acceptance criteria. The results confirmed the reliability of the calculation codes ANGLE and LabSOCS as alternative efficiency calibration methods in high-purity-germanium gamma spectrometry. This study is likely to promote the further application of the ANGLE and LabSOCS calculation codes in radioactivity measurements.This study reports the performances of efficiency calibrations for high-purity-germanium gamma-ray spectrometry using the source-, Laboratory Sourceless Object Calibration Software(LabSOCS)-and ANGLE-based methods in an inter-comparison exercise. Although the results of LabSOCS and ANGLE for ^(241)Am emitting lowenergy gamma rays were not very satisfactory, all of the three efficiency calibration methods passed acceptance criteria. The results confirmed the reliability of the calculation codes ANGLE and LabSOCS as alternative efficiency calibration methods in high-purity-germanium gamma spectrometry. This study is likely to promote the further application of the ANGLE and LabSOCS calculation codes in radioactivity measurements.

关 键 词:EFFICIENCY CALIBRATION ANGLE Laboratory Sourceless Object CALIBRATION Software (LabSOCS) GAMMA-RAY SPECTROMETRY 

分 类 号:TL[核科学技术]

 