降补固态软起动在催化裂化装置主风机中的应用  

APPLICATION OF REDUCING COMPENSATION SOLID SOFT START ON THE MAIN AIR BLOWER IN CATALYTIC AND CRACKING UNIT

在线阅读下载全文

作  者:李化训 Li Huaxun(Operation and Maintenance Center of Qilu Branch Co., SINOPEC, Zibo Shandong 255400)

机构地区:[1]中国石化齐鲁分公司运行维护中心,山东淄博255400

出  处:《齐鲁石油化工》2019年第1期70-74,共5页Qilu Petrochemical Technology

摘  要:针对齐鲁炼油厂第3套2.60 Mt/a催化裂化装置2台主风机容量大、起动电流10 kA左右,会严重拉低10 kV供电系统的问题。选用降补固态软起动装置TCS6-25000进行降压起动,可显著降低起动电流,减小母线压降,确保供电系统稳定运行。Aimed at large capacity and about 10kA starting current of the two main air blower on the 3rd 2.6 Mt/a catalytic and cracking unit in Qilu Refinery, which pulled down seriously the 10 kA power supply system, reduced voltage starting was executed by selecting reducing compensation solid soft start unit TCS6-25000. The starting current was decreased obviously, and voltage drop of the bus was reduced. Stable running of the power supply system was ensured.

关 键 词:降补固态软起动 大电动机 降压起动 起动电流 

分 类 号:TP272[自动化与计算机技术—检测技术与自动化装置]

 