超高效液相色谱法快速测定人血浆中替考拉宁的浓度及其应用  被引量:6

Rapid Determination of Teicoplanin Concentration in Human Plasma by UPLC and Its Application

在线阅读下载全文

作  者:时正媛[1,2,3] 庄健美 顾红燕 杨欣妤[1,2,3] 鄢丹 SHI Zheng-yuan;ZHUANG Jian-mei;GU Hong-yan;YANG Xin-yu;YAN Dan(Department of Pharmacy, Beijing Shijitan Hospital Affiliated to Capital University of Medical Sciences, Beijing 100038, China;Department of Blood Transfusion, Beijing Shijitan Hospital Affiliated to Capital University of Medical Sciences, Beijing 100038, China;Beijing Key Laboratory of Bio-characteristic Profiling for Evaluation of Rational Drug Use, Beijing Shijitan Hospital Affiliated to Capital University of Medical Sciences, Beijing 100038, China;Joint Laboratory for International Cooperation of Bio-characteristic Profiling for Evaluation of Clinical Rational Drug Use Evaluation, Beijing Shijitan Hospital Affiliated to Capital University of Medical Sciences, Beijing 100038, China)

机构地区:[1]首都医科大学附属北京世纪坛医院药剂科,北京100038 [2]首都医科大学附属北京世纪坛医院临床合理用药生物特征谱学评价北京市重点实验室,北京100038 [3]首都医科大学附属北京世纪坛医院临床合理用药生物特征谱学评价国际合作联合实验室,北京100038 [4]首都医科大学附属北京世纪坛医院输血科,北京100038

出  处:《中国药学杂志》2019年第6期484-488,共5页Chinese Pharmaceutical Journal

基  金:国家自然科学基金项目资助(81773891);国家"重大新药创制"科技重大专项项目资助(2017ZX09301-040);北京世纪坛医院院基金项目资助(2017-C03)

摘  要:目的建立超高效液相色谱法(UPLC)快速测定人血浆中替考拉宁的浓度。方法分析色谱柱为Acquity UPLC BEHC18(2.1 mm×50 mm,1.7μm)。流动相A为含20 mmol·L^(-1)乙酸铵的超纯水,流动相B为乙腈。柱温:35℃。流速为0.5mL·min^(-1),梯度洗脱。检测波长为215 nm。用哌拉西林钠为内标。采用SPSS对内标法和外标法的计算结果进行配对t检验,以考察两种计算结果是否存在差异。结果人血浆替考拉宁线性范围为3.125~100.00μg·mL^(-1)(r=0.999 9)。内标法与外标法计算结果无显著性差异,可相互转换。结论该方法灵敏、回收率高、重现性好,适用于人血浆中替考拉宁浓度监测,指导临床合理用药。OBJECTIVE To establish a rapid ultra-high performance liquid chromatography method for determining teicoplanin concentration in human plasma. METHODS The samples were chromatographed on Waters Acquity UPLC BEH-C18 column using gradient elution method(mobile phase A:20 mmol·L^-1 ammonium acetate;mobile phase B:acetonitrile). The absorption wavelength was set at 215 nm. The column temperature were maintained at 35 ℃. The teicoplanin concentration was calculated by internal standard method and external standard method, respectively. The results of the two methods were compared by paired t-test using SPSS statisticals software. RESULTS The liner range of the calibration curve for teicoplanin was 3.15-100 μg·mL^-1(r=0.999 9). The concentrations calculated by the two methods had good correlation without significant difference. CONCLUSION This method is proved to be rapid, sensitive and suitable for the therapeutic drug monitoring and pharmacokinetic investigation of teicoplanin in human plasma.

关 键 词:替考拉宁 超高效液相色谱法 二极管阵列检测器 血浆浓度 

分 类 号:R969[医药卫生—药理学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象