SS_4改型电力机车高压电压互感器内部放电原因分析及改进建议  被引量:2

Cause Analysis and Improvement Suggestions for Internal Discharge of HV Voltage Transformer of Modified SS_4 Electric Locomotive

在线阅读下载全文

作  者:王永强 WANG Yongqiang

机构地区:[1]中国铁路郑州局集团有限公司新乡机务段,河南新乡453000

出  处:《铁道技术监督》2019年第3期37-39,45,共4页Railway Quality Control

摘  要:中国铁路郑州局集团有限公司洛阳机务段配属SS_4改型电力机车高压电压互感器在运用中发生内部放电故障。结合现场实际解体测量,分析原因,对电压互感器套管制造厂和电压互感器中修厂提出改进建议,同时更换所有存在故障隐患的高压电压互感器,避免放电故障的扩大发展。Internal discharge is detected during the HV voltage transformer application of modified SS4 electric locomotive that are assigned to the locomotive depot of China Railway Zhengzhou Bureau Group Co., Ltd.. In combination of actual field disassembly measurement, the article analyses the reason and gives some improvement suggestions to the voltage transformer bushing manufacturers and the voltage transformer medium repair plants. In the meantime, it suggests to replace all HV voltage transformers with hidden troubles in the locomotive depot, thus avoiding the development of discharge failures.

关 键 词:SS4改型电力机车 高压电压互感器 放电故障 原因分析 改进建议 

分 类 号:U264.3[机械工程—车辆工程]

 