Study on element detection and its correction in iron ore concentrate based on a prompt gamma-neutron activation analysis system  被引量:5

Study on element detection and its correction in iron ore concentrate based on a prompt gamma-neutron activation analysis system

在线阅读下载全文

作  者:Long Zhao Xu Xu Jing-Bin Lu Ya-Lin Gong Xiang-Lin Li Wei Zhang Qing-Min Shang Qing-Feng Song Yan-Feng Li 

机构地区:[1]College of Physics, Jilin University [2]Dandong Dongfang Measurement & Control Technology Co., Ltd [3]Hunan First Normal University

出  处:《Nuclear Science and Techniques》2019年第4期44-52,共9页核技术(英文)

基  金:supported by the National Key Scientific Instrument and Equipment Development Projects(No.2012YQ240121);Liaoning science and technology project(No.2017220010);Changchun Science and Technology Bureau Local Company and College(University,Institution)Cooperation Projects(No.17DY023)

摘  要:A prompt gamma-neutron activation analysis(PGNAA) system was developed to detect the iron content of iron ore concentrate. Because of the self-absorption effect of gamma-rays and neutrons, and the interference of chlorine in the neutron field, the linear relationship between the iron analytical coefficient and total iron content was poor, increasing the error in the quantitative analysis. To solve this problem, gamma-ray self-absorption compensation and a neutron field correction algorithm were proposed, and the experimental results have been corrected using this algorithm. The results show that the linear relationship between the iron analytical coefficient and total iron content was considerably improved after the correction. The linear correlation coefficients reached 0.99 or more.A prompt gamma-neutron activation analysis(PGNAA) system was developed to detect the iron content of iron ore concentrate. Because of the self-absorption effect of gamma-rays and neutrons, and the interference of chlorine in the neutron field, the linear relationship between the iron analytical coefficient and total iron content was poor, increasing the error in the quantitative analysis. To solve this problem, gamma-ray self-absorption compensation and a neutron field correction algorithm were proposed, and the experimental results have been corrected using this algorithm. The results show that the linear relationship between the iron analytical coefficient and total iron content was considerably improved after the correction. The linear correlation coefficients reached 0.99 or more.

关 键 词:PROMPT gamma-neutron activation analysis SELF-ABSORPTION Energy spectrum Compensation CORRECTION Iron ORE CONCENTRATE 

分 类 号:TL[核科学技术]

 