摘  要:针对传统10kV,650A的中压开关柜柜内导电排尺寸偏大的问题,对其进行优化设计将有效节约有色金属耗量,利用Solidworks建立三维模型并利用ANSYS Maxwell有限元电磁仿真软件进行仿真计算,模拟仿真改进后10kV开关柜导电排的热效应及力效应,证明了改进设计是合理的,并为开关柜导电排的工程施工提供了理论参考。In view of the big size of traditional conductor bar of medium voltage switchgear with 10 kV, 650 A, the optimizing design to which will save the cost of non-ferrous metal.This paper makes simulation algorithm based on the software of Solidworks and ANSYS Maxwell to simulate the heat effect and force effect of the optimized conductor bar with 10 kV.The results prove that this design is reasonable,and provide some theoretical reference for the construction of conductor bar of media voltage switchgear.