作  者:汤同欢 陈丙法 金婧梅 陈开宁[2] 李勇[1] 黄蔚[2] TANG Tong-huan;CHEN Bing-fa;JIN Jing-mei;CHEN Kai-ning;LI Yong;HUANG Wei(School of Ejwironmental Science and Engineering, Suzhou University of Science and Technology, Suzhou 215000, China;State Key Laboratory of Lake Science and En/vironment, Nanjing Institute of Geography and Limnology, Chinese Academy cf Sciences, Nanjing 210008 , China;University of Chinese Academy of Sciences, Beijing 100049, China)

机构地区:[1]苏州科技大学环境科学与工程学院,江苏苏州215000 [2]中国科学院南京地理与湖泊研究所湖泊环境与工程国家重点实验室,江苏南京210008 [3]中国科学院大学,北京100049

出  处:《中国给水排水》2019年第5期19-23,29,共6页China Water & Wastewater

基  金:国家水体污染控制与治理科技重大专项(2017ZX07603-05);国家自然科学基金资助项目(51409166);太湖水污染治理专项资金资助项目(TH2016401)

摘  要:针对纳污河水碳氮比较低的问题,采用芦苇碳源后置反硝化生物滤池(Post-DBF)强化反硝化脱氮,重点考察了进水量(17. 28、28. 80、43. 20 L/d)对系统脱氮效果的影响。当进水量为17. 28 L/d时,后置反硝化滤池对COD、TN和NH4^+-N的去除率分别为78. 81%、78. 23%和70. 21%,出水水质达到了《城市污水再生利用景观环境用水水质》(GB/T 18921—2002)标准。其中,Post-DBF的硝化段可以去除大部分有机物,占系统总去除率的87. 34%。在进水与芦苇碳源有足够长接触时间(> 2. 6 h)的情况下,芦苇能够为系统缺氧段提供一定的碳源,使反硝化过程得以稳定进行,弥补了传统低碳氮比污水因碳源不足而产生的脱氮效率低下的缺陷。Reed carbon source was added to the post denitrification biofilter ( Post-DBF) to enhance the nitrogen removal in the low C/N ratio polluted river water, and the effects of influent flow (17.28 L/d, 28. 80 L/d and 43. 20 L/d) on the denitrification efficiency were investigated. When the influent flow was 17. 28 L/d, the mean removal rates of COD, TN and NH4^+- N of Post-DBF were 78. 81%, 7. 23% and 70. 21% respectively, and the effluent quality reached the standard of The Reuse of Urban Recycling Water-Water Quality Standard for Scenic Environment Use ( GB/T 18921 - 2002 ). The nitrification stage of Post-DBF could remove most of the organic matter, accounting for 87. 34% of the total removal rate of the system. In case of the influent and reed carbon source had enough contact time (>2. 6 h), reed straw could provide carbon source for the anoxic denitrification process, making up for the low denitrification efficiency of low C/N ratio wastewater.

关 键 词:后置反硝化 固体碳源 生物滤池 低碳氮比 

分 类 号:TU992[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象