检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陆安军 苏梦晓 LU An-jun;SU Meng-xiao(Guangxi 4th Geology Team, Nanning 530031, China)
出 处:《冶金分析》2019年第4期53-59,共7页Metallurgical Analysis
摘 要:中低品位铝土矿种类繁多,Al_2O_3含量较低,而其他组分较为复杂,常富含Fe_2O_3、CaO、MgO、S等组分,应用熔融制样-X射线荧光光谱法(XRF)测定富含Fe_2O_3、S的样品在熔融时会腐蚀铂-金坩埚,样品流动性差,而且高温下S挥发严重。实验使用NH_4NO_3作为氧化剂,采用熔融法制样,建立了波长色散X射线荧光光谱法同时测定中低品位铝土矿和高硫铝土矿中Al_2O_3、SiO_2、Fe_2O_3、CaO、TiO_2、K_2O、Na_2O、MgO、P_2O_5、S的分析方法。为了拓宽Fe_2O_3、S等组分的含量范围,采用国家标准物质之间互相配制和经多次化学分析的样品来绘制校准曲线;通过试验确定样品与熔剂的稀释比为1∶20,加入1.0g NH_4NO_3作为氧化剂,滴加0.5mL LiBr溶液作脱模剂,在1 050℃下熔样8min,可制得透彻、玻璃化程度高的样片。各组分的检出限在27.7~259μg/g之间,各组分测定结果的相对标准偏差(RSD,n=12)小于3%。经实际样品分析,各组分测定值与其他方法分析结果相吻合,有效解决了富含Fe_2O_3、S的中低品位铝土矿和高硫铝土矿的制样问题及S不易被准确测定的难题,可用于测定S质量分数15%以内的铝土矿样品。There is a great variety of medium-low grade bauxite. The content of Al 2O 3 is low and the composition of other components is complicated. It usually contains rich Fe 2O 3, CaO, MgO and S. During the determination of samples containing rich Fe 2O 3 and S by X-ray fluorescence spectrometry (XRF) after fusion sample preparation, the platinum-gold crucible can be corroded in sample melting. Moreover, the flowability of sample is poor and the volatilization of S at high temperature is serious. NH 4NO 3 was used as oxidizing agent for fusion sample preparation. The simultaneous determination method of Al 2O 3, SiO 2, Fe 2O 3, CaO, TiO 2, K 2O, Na 2O, MgO, P 2O 5 and S in medium-low grade bauxite and high-sulfur bauxite by wavelength dispersive X-ray fluorescence spectrometry was established. In order to broaden the content range of components such as Fe 2O 3 and S, the calibration curve was plotted using the national standard substances and samples after chemical analysis. The dilution ratio of sample and flux was 1∶20. In experiments, 1.0 g of NH 4NO 3 was used as oxidizing agent and 0.5 mL of LiBr solution was used as release agent. After fusion at 1 050 ℃ for 8 min, the transparent sample pellet with high vitrifaction degree could be prepared. The detection limits of components ranged from 27.7 μg/g to 259 μg/g. The relative standard deviations (RSD, n =12) of determination results were all less than 3%. The actual sample was analyzed and the found results were consistent with those obtained by other methods. The proposed study effectively solved the sample preparation problem for Fe 2O 3 and S-rich medium-low grade bauxite and high-sulfur bauxite as well as the problem that the content of S was difficult to be accurately determined. The proposed method was applicable for the analysis of bauxite samples with S content less than 15%.
关 键 词:波长色散X射线荧光光谱法 中低品位铝土矿 高硫铝土矿 熔融制样 主次组分
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.119.126.21