地下与地上钢筋混凝土矩形结构抗震性能对比研究  被引量:7

Comparative Study on the Seismic Performances of Underground vs. Above-Ground Reinforced Concrete Structures with Rectangular Cross Sections

在线阅读下载全文

作  者:刘晶波[1] 兰兴欢 谭辉[1] LIU Jingbo;LAN Xinghuan;TAN Hui(Department of Civil Engineering,Tsinghua University,Beijing 100084,China)

机构地区:[1]清华大学土木工程系,北京100084

出  处:《地震工程学报》2019年第2期271-277,共7页China Earthquake Engineering Journal

基  金:国家自然科学基金(51478247);国家自然科学基金重大研究计划集成项目(91215301)

摘  要:地下结构由于受周围土体的约束作用,其受力与变形特点与地上结构存在差异。采用Pushover分析方法分别对考虑土-结构相互作用的地下结构和不考虑土体的地上结构的抗震性能进行对比研究,探讨单层单跨和单层双跨钢筋混凝土矩形结构在有、无土体存在时抗震性能的差异。研究表明:考虑土-结构相互作用的地下结构变形能力与无土体时存在差异。在相同结构尺寸与初始轴压比的情况下,考虑土-结构相互作用的地下结构弹性层间位移角限值变小,地下结构更早出现塑性铰;单跨地下结构变形能力比地上结构的差,周围土体的剪切变形约束作用使得地下结构的延性变差;双跨地下结构与地上结构中柱变形能力相差不多,但侧墙的变形能力比地上结构的略差。因此,即使相同尺寸和初始轴压比的钢筋混凝土矩形结构,地上与地下结构的抗震性能仍存在较大差异,地上结构的相关研究成果不宜直接用于地下结构。The seismic performance of underground structures differs from that of above-ground structures due to the confinement effect of surrounding soil.This paper compares the seismic performances of underground structures,considering soil-structure interaction (SSI),with above-ground structures,without considering soil,by means of the Pushover analysis method.Two kinds of reinforced concrete single-story structures with rectangular cross sections were chosen,including single-span and two-span.The research results showed that the seismic deformation of underground and above-ground structures is different.Under similar conditions,namely,with the same structure size and initial axial compression ratio,the elastic inter-story drift limit of underground structures was less than that of above-ground structures,and the plastic hinge for underground structures appeared earlier.The deformability of the underground single-span structure was weaker because of the shear deformation constraint of the surrounding soil.While the deformability of the central column of the underground two-span structure was nearly the same as that of the above-ground structure,the deformability of the lateral wall of the underground two-span structure was a bit weaker than that of above-ground two-span structure.In conclusion,even with the same structure size and initial axial compression ratio,the seismic performances of underground structures and above-ground structures are different.Therefore,existing research concerning above-ground structures is not applicable to underground structures.

关 键 词:地下结构 土-结构相互作用 抗震性能 PUSHOVER分析 弹性层间位移角限值 

分 类 号:TU375[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象