检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈伟[1] 段芯[1] 裴喜平[1] CHEN Wei;DUAN Xin;PEI Xi-ping(College of Electrical and Information Engineering,Lanzhou Univ.of Tech.,Lanzhou730050,China)
机构地区:[1]兰州理工大学电气工程与信息工程学院,甘肃兰州730050
出 处:《兰州理工大学学报》2019年第2期90-96,共7页Journal of Lanzhou University of Technology
基 金:国家自然科学基金(51767017);甘肃省基础研究创新群体项目(18JR3RA133)
摘 要:针对电压暂降随机预估中传统蒙特卡洛法认为线路长度是影响线路故障率唯一影响因素的缺陷,提出了一种改进的电压暂降概率评估方法.构建了包含线路自身属性及多种客观因素的线路故障概率评估体系;并结合该评估体系,建立了完善的短路故障模型,在PSCAD/EMTDC搭建IEEE-30节点系统仿真模型,运用随机数发生模块和Multiple Run组件对故障信息进行抽样和传送,通过仿真计算得到敏感负荷接入点的电压暂降特征量和评估指标的概率分布.仿真结果表明,改进的蒙特卡洛法相比于蒙特卡洛法在电压暂降概率评估中更接近电网的真实状况,验证了该方法的有效性.Aimed at the shortage of the traditional Monte Carlo method for stochastic assessment of voltage sags, where the length of transmission line is taken as the unique influencing factor on line failure rate, an improved method for assessment of voltage sag probability is proposed. A probability assessment system of line fault is established, in which the attribute of the line proper and variety of objective factors are included and with the aid of it, a perfect short-circuit fault model is established. The IEEE-30 nodal system simulation model is then established on PSCAD/EMTDC, the random number generation module and Multiple Run component are used to sample and transmit the fault information, and the probability distribution of voltage sag characteristic variable and assessment index of the sensitive load access point are obtained by means of simulative evaluation. The simulation result shows that compared to original Monte Carlo, the improved method for assessment of voltage sag probability will be closer to real condition of grid system and the effectiveness of this method will be verified.
关 键 词:电压暂降 随机预估 故障状态变量 PSCAD/EMTDC 概率分布
分 类 号:TM714[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15