作 者:W.R.Reed G.J.Joy M.Shahan S.Klima G.Ross
机构地区:[1]Centers for Disease Control anti Prevention, National Institute for Occupational Safety and Health, 626 Cochrans Mill Rd.,Pittsburgh,PA 15236,USA [2]J.H Fletcher & Co.,Inc.,402 High St.,Huntington,WV 25705,USA
出 处:《International Journal of Coal Science & Technology》2019年第1期15-26,共12页国际煤炭科学技术学报(英文)
摘 要:Testing was completed on an earlier roof bolter CAC that used slots to provide a perimeter airflow. NIOSH tested it due to its unique design that differed from canopies that provided uniform airflow. Based upon NIOSH recommendations from the earlier testing, a 3rd generation roof bolter CAC has been developed by J.H. Fletcher & Co. The changes to this CAC involve design modifications to the plenum outlets, using a single row of outlets on the perimeter and a different material for the plenum. This laboratory testing was a continuation of the original perimeter slotted CAC design. Using gravimetric and instantaneous sampling of respirable dust concentrations underneath and outside of the CAC. the laboratory testing was completed using three different blower fans that delivered differing airflows. The maximum plenum airflow velocities ranged from 2.34 to 3.64 m/s (460-716 fpm). Results showed plenum respirable dust concentrations ranging from 34.6% to 49.3% lower than respirable dust concentrations outside the plenum protection zone, thus showing an improvement in protection for the roof bolter operators.
关 键 词:ROOF bolter Respirable DUST CANOPY air CURTAIN COAL mining
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15