伍迪BM2.7型离子膜电解装置优化改造  

Optimization and transformation of Uhdenora BM 2.7 ion-exchange membrane electrolysis device

在线阅读下载全文

作  者:靳党会 张国文 张明 杨莉 JIN Danghui;ZHANG Giwwen;ZHANG Ming;YANG Li(Shaanxi Beiyuan Chemical Group Co. , Ltd. , Yulin 719319 , China)

机构地区:[1]陕西北元化工集团股份有限公司

出  处:《氯碱工业》2019年第4期18-20,共3页Chlor-Alkali Industry

摘  要:主要对离子膜电解装置运行过程中存在的阳极液卸料罐溢流口氯气泄漏、单槽切系统氯氢压差无法平稳控制以及脱氯后淡盐水罐液位频繁波动问题进行原因分析,对现有装置提出优化改造措施,保证系统安全平稳运行。Some problems occurred in the operation of ion membrane electrolysis device, such as the leakage of chlorine from the overfall of the anolyte discharge tank, out-of-control pressure difference between chlorine and hydrogen at the time of switching off a cell, and the frequent fluctuation of the liquid level of dechlorinated and depleted brine tank. The causes were analyzed. Transformation measures were put forward to ensure safe and stable operation.

关 键 词:离子膜电解槽 氯气泄漏 氯氢压差 双法兰差压式液位计 

分 类 号:TQ114.262[化学工程—无机化工]

 