检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:徐永海[1] 李晨懿 汪坤 卢文清 Xu Yonghai;Li Chenyi;Wang Kun;Lu Wenqing(State Key Laboratory of Alternate Electrical Power System With Renewable Energy Sources North China Electric Power University Beijing 102206 China;Chengdong Power Supply Center State Grid Chengdu Electric Power Supply Company Chengdu 610011 China)
机构地区:[1]华北电力大学新能源电力系统国家重点实验室,北京102206 [2]国网成都供电公司城东供电中心,成都610011
出 处:《电工技术学报》2019年第10期2216-2229,共14页Transactions of China Electrotechnical Society
基 金:国家自然科学基金重点项目(51277069)资助
摘 要:通过机理分析和试验研究,深入分析变频器受电压暂降影响的现象和机理。选取国内市场有代表性的七种品牌的中小功率(7.5kW和18.5kW)低压变频器,测试多种因素对变频器暂降耐受特性的影响,并通过对13 000余组试验数据的综合分析与处理提取低压变频器在最严重暂降类型(三相暂降)下的通用耐受曲线。提出一种考虑不确定区域兼容概率的兼容性分析方法,以试验数据和实测电网电压暂降事件作为样本数据,利用对数变换改进的最大熵法建立变频器不确定区域的故障概率模型以及电网暂降幅值和持续时间的概率分布模型,计算不确定区域中的兼容概率和总兼容次数,并与其他概率拟合方法和传统兼容性分析方法进行比较,验证了本文方法的有效性和精确性。Firstly, the performance and mechanism of the variable-frequency drive (VFD) affected by voltage sags were deeply analyzed by theoretical analysis and experiments. Then, 7 representative brands of VFDs in domestic market with small and medium power (7.5kW & 18.5kW) were selected as the samples. The influence of various factors was tested on the sample VFDs. Further, the general tolerance curves of VFDs under the most severe sag type (three-phase sag) were obtained by comprehensive analysis of more than 13 000 groups of test data. Moreover, a method considering the compatibility probability of uncertain region was proposed. In this method, based on test data and measured sags, the probability distribution models were established using the modified maximum entropy method improved by logarithmic transformation, which include the models of fault probability of VFDs in uncertain region and amplitude and duration of sags in the distribution system. Then, the compatibility probability in uncertain area and total numbers for no trip were calculated. Finally,compared with other probabilistic fitting methods and traditional compatibility analysis methods, the validity and accuracy of the proposed method were verified.
关 键 词:变频器 电压暂降 耐受曲线 兼容性 试验 最大熵法
分 类 号:TM76[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222