篦冷机堆“雪人”的故障分析及处理  被引量:1

Fault Analysis and Treatment of Grate Cooler Accumulating “snowman”

在线阅读下载全文

作  者:赵晓东[1] ZHAO Xiaodong(Chongqing College of Electronic Engineering, Chongqing 401331)

机构地区:[1]重庆电子工程职业学院,重庆401331

出  处:《水泥技术》2019年第3期65-68,共4页Cement Technology

摘  要:分析了原燃料的质量、熟料的液相量、飞砂料、篦冷机及煤粉燃烧器操作等因素对堆"雪人"的影响,提出了控制原燃材料的质量、调控熟料配料方案、正确操作篦冷机及煤粉燃烧器等相应处理技术措施,总结了实施改进技术措施后的生产实践效果。The influences of the quality of the original and combustion materials, liquid phase quantity of clinker, flying sand, grate cooler and pulverized coal burner on the“snowman”are analyzed. Put forward the control of the quality of the original and combustion materials, control of clinker batching scheme, the correct operation of grate cooler and pulverized coal burner and other corresponding treatment technical measures. The production practice effect after implementing the improvement measures is summarized.

关 键 词:篦冷机 “雪人” 原因分析 措施 实践效果 

分 类 号:TQ172.622.4[化学工程—水泥工业]

 