作 者:李博[1] 陈国龙 宁宁 朱浩祎[4] 赵文刚 LI Bo;CHEN Guo-long;NING Ning;ZHU Hao-yi;ZHAO Wen-gang(Electrical and Electronic Engineering Department, Yingkou Vocational and Technical College, Yingkou Liaoning 115000;Planning Review Center, State Grid Liaoning Economic Research Institute,Shenyang Liaoning 110015;Business and Electricity Bill Room, State Grid Yingkou Electric Power Supply Company,Yingkou Liaoning 115000;Electric Power Design Institute, State Grid Panjin Electric Power Supply Company, Panjin Liaoning 124010)
机构地区:[1]营口职业技术学院电气电子工程系,辽宁营口115000 [2]国网辽宁经研院规划评审中心,辽宁沈阳110015 [3]国网营口供电公司营业及电费室,辽宁营口115000 [4]国网盘锦供电公司电力设计研究所,辽宁盘锦124010
出 处:《辽宁师专学报(自然科学版)》2019年第1期71-75,共5页Journal of Liaoning Normal College(Natural Science Edition)
摘 要:为实现四层以下多层土壤水平接地网接地电阻的计算,从而满足工程设计的实际需要,利用公式法中两层土壤水平接地网接地电阻计算公式进行拓展,引入两层土壤分解法合成等效土壤电阻率,搭建计算模型.依据计算模型编制软件程序,实现多层土壤情况下水平接地网接地电阻计算.与公开发表的计算机数值计算法得值相比较,计算结果误差保持在±10%以内,验证了计算模型的有效性,软件可以使用.In order to realize the calculation of grounding resistance of multi-layer soil horizontal grounding grid under four layers and meet the actual needs of engineering design, the formula of grounding resistance of two-layer soil horizontal grounding grid is extended by the formula method, and the equivalent soil resistivity is synthesized by two-layer soil decomposition method, and the calculation model is established. According to the calculation model, a software program is compiled to calculate the grounding resistance of horizontal grounding grid in multi-layer soil. Comparing with the published values obtained by the computer numerical calculation method, the error of the calculation results is kept within ±10%, which verifies the validity of the calculation model and the software can be used.
分 类 号:TM862[电气工程—高电压与绝缘技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222