被动式节能混凝土复合外墙的材料优化与性能研究  被引量:7

Study on material optimization and performance of passive energy-saving concrete composite external wall

在线阅读下载全文

作  者:张昊天[1] 罗芙蓉 戴吉祥 周俊杰 ZHANG Haotian;LUO Furong;DAI Jixiang;ZHOU Junjie(Changchun Institute of Architecture,Changchun 130021,China;Beijing University of Civil Engineering and Architecture,Beijing 100044,China)

机构地区:[1]长春建筑学院,吉林长春130021 [2]北京建筑大学,北京100044

出  处:《新型建筑材料》2019年第5期103-105,133,共4页New Building Materials

摘  要:设计了由防火层、保温层和结构层组成的轻质混凝土复合外墙板,研究了外墙板结构层轻质混凝土的材料配比对坍落度和密度的影响,制作了轻质混凝土外墙板并针对性测试了保温性能。结果表明,水胶比为0.38、砂率为0.47时,轻质混凝土坍落度为120mm、密度为1849kg/m^3,且不会出现泌水和难搅拌现象,是适宜的轻骨料混凝土配比;轻质保温混凝土外挂板标准试件的热阻为3.42(m^2·K)/W、传热系数为0.29W/(m^2·K),符合节能设计要求,具有良好的保温效果。A lightweight concrete composite exterior wall panel is designed,which is composed of fire-proof layer,thermal insulation layer and structural layer.The influence of the material ratio of the structural layer on the slump and unit weight of the concrete is studied.The lightweight concrete exterior wall panel is manufactured and its thermal insulation performance is tested.The results show that the slump of lightweight concrete is 120 mm and the bulk density is 1849 kg/m3 when the water-binder ratio is 0.38 and the sand ratio is 0.47,and there is no bleeding and difficult mixing,so it is a suitable proportion of lightweight aggregate concrete,the thermal resistance of the standard specimen of lightweight insulation concrete is 3.42(m^2·K)/W,and the heat transfer coefficient is 0.29 W/(m^2·K),which conforms to the energy-saving design,and it has good insulation effect.

关 键 词:轻质混凝土 外墙板 结构层 配合比设计 保温 

分 类 号:TU111.4[建筑科学—建筑理论]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象