检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:艾竹 韩绮嘉 梁健科 向之明 AI Zhu;HAN Qijia;LIANG Jianke;XIANG Zhiming(Department of Radiology, Panyu Center Hospital of Guangzhou,Guangzhou 511400, China)
机构地区:[1]广州市番禺区中心医院放射科
出 处:《中国医学影像技术》2019年第6期909-913,共5页Chinese Journal of Medical Imaging Technology
基 金:国家自然科学基金(81671853);广东省自然科学基金(2015A030313753);广州市民生科技重大专项(2019);广州市科学研究专项(201510010002);广州市番禺区科技计划重点学科项目(2017-Z04-12);广州市番禺区科技计划项目(2014-Z03-24)
摘 要:目的探讨体素内不相干运动(IVIM)DWI条件下心电门控技术对肝脏图像质量和参数测量的影响。方法前瞻性收集20名志愿者行IVIMDWI,采用自由呼吸和心电门控扫描,并对所得图像进行主观评分,测量肝左、右叶SNR、ADC值及IVIM各参数值[真扩散系数(D)、假扩散系数(D~*)、灌注分数(f)]。采用Wilcoxon符号秩和检验比较肝脏图像主观质量评分,以配对t检验比较SNR、ADC值及IVIM各参数值,以Bland-Altman方法评价各参数值的一致性。结果采用心电门控技术所得图像质量主观评分明显高于自由呼吸(P均<0.01);不同b值时采用心电门控技术测得肝左叶SNR均高于自由呼吸图像(P<0.01),肝左叶ADC、f值均低于自由呼吸图像(P均<0.05),而D值则高于自由呼吸图像(P<0.05)。采用心电门控技术肝左叶D、D~*和f值的一致性好于自由呼吸图像。结论心电门控IVIMDWI可获得较好的图像质量,有效克服心脏搏动对肝左叶各参数值数据测量的影响。Objective To investigate the influence of ECG-triggered technique on imaging quality and parameters in diffusion weighted intravoxel incoherent motion imaging(IVIM DWI). Methods Twenty young healthy volunteers underwent liver IVIM DWI examination were enrolled, the images were obtained with ECG-triggered and free breath, and SNR, ADC and parameters of IVIM(true-diffusion coefficient [D], pseudo-diffusion coefficient [D~*], perfusion fraction [f]) of the left and right lobe of liver were acquired. The scores of liver imaging quality was analyzed with Wilcoxon sign rank sum test. The SNR, ADC, D, D~* and f values were analyzed with paired-samples t test. The consistency of ADC, D, D~*, and f were assessed with the Bland-Altman method. Results The scores of liver imaging quality of ECG-triggered were significantly higher than those of free breath(all P<0.01). Under different b values, SNR of left lobe of liver with ECG-triggered were higher than those of the free breath(all P<0.01). The values of ADC and f of left lobe of liver with ECG-triggered were statistically lower than those of free breath(both P<0.05), but the values of D were higher than that of free breath(P<0.05). The consistency of left lobe of liver with ECG-triggered was better than that with free breath. Conclusion IVIM DWI combined with ECG-triggered can be used to obtain better imaging quality and effectively overcome the interference of heart beating on parameters measuring in left lobe of liver.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28