检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:金玉[1,2] 易伟建[1] 胡岚[1] 马克俭[1,3] Jin Yu;Yi Weijian;Hu Lan;Ma Kejian(College of Civil Engineering, Hunan University, Changsha 410082, P. R. China;Architecture Engineering College, Jiaxing University, Jiaxing 314001, Zhejiang, P. R. China;Research Center of Space Structure, Guizhou University, Guiyang 550003, P. R. China)
机构地区:[1]湖南大学土木工程学院,长沙410082 [2]嘉兴学院建筑工程学院,浙江嘉兴314001 [3]贵州大学空间结构研究中心,贵阳550003
出 处:《土木与环境工程学报(中英文)》2019年第3期77-84,共8页Journal of Civil and Environmental Engineering
基 金:国家自然科学基金(51178175;51338004)~~
摘 要:为研究配置不同参数栓钉钢筋混凝土双向板的受力性能,完成了7块配置栓钉的双向板柱节点冲切试验,主要研究栓钉间距、直径、高度、强度和布置形式等参数变化对受力性能的影响,采用静力加载方式模拟配置栓钉的板柱节点破坏全过程。对比分析试验结果发现,增大栓钉直径、栓径高度或提高栓钉强度均能改善试件抗冲切性能,其中,增大直径效果最为明显,抗变形能力提高幅度达到36%;加大栓钉间距和减小栓钉高度对改善试件抗冲切性能不利,承载能力和抗变形能力均有不同程度降低;对比3种不同栓钉布置形式发现,采用相同数量栓钉放射布置和增加每圈栓钉数量的正交布置,均有利于提高试件抗冲切能力,但前者更经济。对比分析相关规范计算结果和试验结果发现,规范对配栓钉板柱结构的计算结果具有足够的安全储备,但对于反映试验结果的实质不够充分,特别是栓钉对板的抗冲切性能的贡献有所低估。This paper aims to study the mechanical performances of reinforced concrete two-way slab with different stud parameters.The experimental study on seven reinforced concrete two-way slab-column connections with punching shear studs was conducted.The main parameters investigated were spacing of stud,the diameter of the stud,the height of the stud,the strength of the stud and the arrangement of the stud.The whole process of damage of slab-column connections with studs was simulated using static loading method.The results show that increasing the diameter of the stud,the height of the stud or the strength of the stud can improve the anti-punching shear performance of the specimen.The increase in diameter is the most obvious,and the decrease in deformation is up to 36%.Increasing stud spacing and reducing stud height weaken the load-bearing capacity and thus the deformation are increased.By comparing three different stud layouts,it is found that using radiation type contributes better to the improvement of the specimen anti-punching shear capacity,and the former was more economical.Then,the accuracy of the test results was verified by comparing the calculated results of relevant specifications with the test results.The results show that the safety reserve of specification calculation results of slabcolumn structure with studs is sufficient.However,it is not enough to reflect the nature of test results,especially contributions of the stud to anti-punching shear performance of slabs are underestimated.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.43