检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:祝逍临 徐合力[1] 高岚[1] ZHU Xiao-lin;XU He-li;GAO Lan(School of Energy and Power Engineering, Wuhan University of Technology, Wuhan 430063, China)
机构地区:[1]武汉理工大学能源与动力工程学院
出 处:《船海工程》2019年第3期147-150,156,共5页Ship & Ocean Engineering
基 金:国家自然科学基金(51679178)
摘 要:为解决光伏-混合储能动力船舶运行中,光伏发电和负载功率接近的临界状态下,蓄电池充放电切换频繁,船舶启动时低电压穿越(LVRT)能力差的问题,在分频协调控制基础上,充分考虑超级电容的剩余电量(SOC),提出一种可变增益值的控制策略,在电力推进负载下进行的仿真实验表明,超级电容SOC可工作在合理区间内,减少蓄电池充放电切换的次数,缩短母线电压恢复的时间。In order to solve the problems of frequent charge-discharge switching of batteries under the critical state of close photovoltaic(PV) power generation and load power in the operation of PV hybrid energy storage power ships,and poor low voltage ride-through(LVRT) capability during ship start-up,a variable gain control strategy was proposed based on the frequencydivision coordinated control and the residual power of super-capacitor(SOC) is fully considered. The simulation experiments under electric propulsion load showed that the super-capacitor SOC can work in a reasonable range,reduce the number of battery charge and discharge switching,and the time of bus voltage recovery.
关 键 词:光伏-混合储能 直流母线 超级电容 低电压穿越 电力推进
分 类 号:U665[交通运输工程—船舶及航道工程]