检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:范胜男 邓君[1] 安晶刚[1] 郝述霞[1] 刘晓惠[1] 孙全富[1] Fan Shengnan;Deng Jun;An Jinggang;Hao Shuxia;Liu Xiaohui;Sun Quanfu(Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China)
机构地区:[1]中国疾病预防控制中心辐射防护与核安全医学所辐射防护与核应急中国疾病预防控制中心重点实验室,北京100088
出 处:《中华放射医学与防护杂志》2019年第6期444-449,共6页Chinese Journal of Radiological Medicine and Protection
摘 要:目的对2017年全国31个省、直辖市和自治区的医疗卫生机构医用辐射防护监测考核评分的20项指标结果进行分析,为进一步促进、优化全国医疗卫生机构医用辐射防护监测提供技术支持和参考。方法依据《医疗卫生机构医用辐射防护监测工作考核评分表》(2017),运用TOPSIS法与秩和比法加权模糊联合方法,对2017年全国医疗卫生机构医用辐射防护监测执行情况进行分析并作出综合评价。结果TOPSIS法与秩和比法加权模糊联合分析显示各指标从高到低排名前3位为:制订方案(组织制定省级实施方案并以行政文件形式下发)、专人负责(有专人负责项目,有各地市参与项目的工作人员名册通许录)和经费保障;后3位为:放射治疗设备检测完成情况、创新和亮点、放射治疗设备全覆盖情况。结论TOPSIS法与秩和比法的模糊联合应用可以为2017年全国医疗卫生机构医用辐射防护监测的执行情况提供综合量化结果,客观评价了各指标的执行情况,总结2017年工作亮点和瓶颈问题,为进一步优化全国医疗卫生机构医用辐射防护监测提供技术支持和参考。Objective To analyze 20 indicators for the evaluation of medical radiation protection monitoring in 31 provinces, municipalities or autonomous regions in 2017 and provide technical support and reference for further optimization of medical radiation protection monitoring projects. Methods According to " medical radiation protection monitoring assessment score sheet for medical and health institutions", a full range of analysis and evaluation was carried out of medical radiation protection monitoring and implementation at nationwide medical and health institutions by using fuzzy combined method of TOPSIS and rank sum ratio. Results TOPSIS method and rank sum ratio weighted fuzzy joint analysis showed that the top three indicators, in descending order, were management of provincial implementation plans, management of project leaders in various cities and management of funds whereas the lowest three indicators were completion of radiotherapy equipment commissioning, innovation and highlights and tcoverage of radiotherapy equipment. Conclusions The fuzzy combined application of TOPSIS method and rank sum ratio method can provide the comprehensive quantitative result for the implementation of medical radiation protection monitoring in 2017, objectively evaluate the implementation of various indicators, summarize the highlights and bottlenecks of work in 2017, and provide technical support and reference for further optimization of medical radiation protection monitoring.
关 键 词:TOPSIS法 秩和比法 医用辐射防护监测 项目评价
分 类 号:R197[医药卫生—卫生事业管理]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145