特高压高补偿度串补线路潜供电弧特性研究  被引量:13

Research on Secondary Arc Characteristics of UHV Lines With High Compensation Degree Series Compensation

在线阅读下载全文

作  者:颉雅迪 何柏娜[1] 孟涛[2] 李辉[3] 宁家兴 孔杰 王乐淼 XIE Yadi;HE Baina;MENG Tao;LI Hui;NING Jiaxing;KONGJie;WANG Lemiao(Shandong University of Technology,College of Electrical and Electronic Engineering,Shandong Zibo 255049,China;Wuhan NARI Limited Liability Company of State Grid Electric Power Research Institute,Wuhan 430074,China;China Electric Power Research Institute,Wuhan 430074,China)

机构地区:[1]山东理工大学电气与电子工程学院,山东淄博255049 [2]国网电力科学研究院武汉南瑞有限责任公司,武汉430074 [3]中国电力科学研究院,武汉430074

出  处:《高压电器》2019年第7期78-86,共9页High Voltage Apparatus

基  金:山东省自然科学基金项目(ZR2016EL17);山东省高等学校科技计划项目(J14LN27)~~

摘  要:高补偿度串补在远距离大容量特高压输电线路中有广阔的发展前景,但串补输电线路发生单相接地故障产生的潜供电流包含高幅值低频分量,不利于电弧快速熄弧。针对此问题,文中基于串补输电线路产生潜供电弧的机理,采用ATP-EMTP电磁暂态程序建立特高压串补系统仿真模型,并分别研究采用小电阻短接故障相串补以及联动旁路串补措施对潜供电流、恢复电压的抑制效果。结果表明,潜供电流的衰减速度与串补被短接或旁路的时刻有关,在断路器跳闸前将串补短接或旁路,可加快电弧熄弧速度。该研究结果对特高压大容量远距离高补偿度串补输电线路的工程设计具有参考价值。The high compensation degree series compensation has broad prospects for development in UHV transmission lines with long distance and large capacity. However,there is a high amplitude low frequency component of the secondary arc current produced by the single phase grounding fault occurring in the series compensation transmission lines,which is not conducive to the arc rapidly extinguishing. To solve this problem,based on the secondary arc current mechanism of series compensated transmission lines,the simulation model of series compensated UHV transmission lines is established by using ATP-EMTP simulation program,and the suppression effects of series compensation of short-connection fault with small resistance and series compensation of linkage bypass on the secondary arc current and recovery voltage are studied respectively. The results show that the decay speed of the secondary arc current is related to the short circuit or bypass time of the series compensation. Shorting or bypassing the series compensation before the breaker trips can increase the arc extinguishing speed. The research results have reference value for the design of UHV and high capacity long distance high compensation degree series compensated transmission lines.

关 键 词:高补偿度串补 潜供电流 恢复电压 短接电阻 联动旁路 

分 类 号:TM75[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象