检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李伟 贾军伟[1] 柴昊[1] 张书锋[1] 张明志[1] 崔鸿飞[1] 刘敬敏[1] 刘展[1] LI Wei;JIA Jun-wei;CHAI Hao;ZHANG Shu-feng;ZHANG Ming-zhi;CUI Hong-fei;LIU Jing-min;LIU Zhan(Beijing Orient Institute for Measurement and Test, Beijing 100086,China)
机构地区:[1]北京东方计量测试研究所
出 处:《宇航计测技术》2019年第4期79-84,共6页Journal of Astronautic Metrology and Measurement
基 金:国家自然科学基金《TDLAS中基于谐波信号的气体绝对吸收强度在线测量算法研究》(11502004)
摘 要:TDLAS技术由于其非接触性、高灵敏度、在线响应速度快等优点,而成为当前气体浓度在线检测技术的重要发展方向之一。确定分子吸收线型函数是应用该技术的前提条件,但是目前尚没有有效的方法在线测量分子吸收线型函数,以至严重影响了TDLAS技术的测量精度,限制了其应用范围。因此,通过吸收光谱理论和波长调制理论研究TDLAS技术中谐波特征参数与分子吸收线型函数的关系,推导出蕴含分子吸收信息的谐波通项表达式,利用谐波信号间的关系特征来消除背景信号、激光强度、调制系数等因素的影响,建立了一种基于谐波信号的绝对吸收强度测量算法。以CO2分子和H2O分子在6982cm-1附近的谱线为例进行数值分析和实验研究,仿真和实验结果表明,根据算法测得的分子吸收光谐波信号谱与理论吸收光谱之间的相对误差不超过5%,进一步提高了TDLAS技术的测量精度,拓宽了其应用范围。TDLAS technology has become one of the important development directions of gas concentration on-line detection technology because of its non-contact,high sensitivity and fast on-line response. Determining the molecular absorption line shape function is the prerequisite for applying this technology. However,there is no effective method for on-line measurement of molecular absorption line shape function,which seriously affects the measurement accuracy of TDLAS technology and limits its application. Therefore,studies the relationship between the characteristic parameters and the molecular absorption line shape function in TDLAS technology through the theory of absorption spectrum and wavelength modulation,and deduces the expression of harmonic terms containing molecular absorption information,eliminating the effects of the background signal,laser intensity,and modulation index according to the relationships between the harmonic signals,and finally establishing the measurement algorithm of absolute absorption intensity based on harmonic signal. The absorption spectral lines of CO2 molecule and H2 O molecule near 6982 cm-1 is taken as an example for numerical analysis and experimental research,and the simulation and experimental results show that the relative error between the theoretical absorption spectrum and the measured molecular absorption spectrum according to the algorithm is less than 5%,which further improves the measurement accuracy of TDLAS technology and broadens its application range.
分 类 号:TN247[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15