Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C  被引量:3

Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C

在线阅读下载全文

作  者:ZHOU Yasu ZHANG Pan ZHAO Jingde YANG Honghai BAI Yufeng 

机构地区:[1]College of Environmental Science and Engineering, Donghua University

出  处:《Journal of Thermal Science》2019年第5期1015-1023,共9页热科学学报(英文版)

摘  要:Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in summer, not for any other conditions, especially in low air wet-bulb temperature areas such as those near 0℃. In addition, CWCTs often fail to achieve the designed cooling effect at low air wet-bulb temperatures. A experiment set of CWCT was built, and the performance of the CWCT at low air wet-bulb temperature near 0℃ was investigated. The impact of the operating parameters(air flow rate, cooling water flow rate, and spray water flow rate) on the heat and mass transfer performance of the CWCT was measured and analyzed. The results show the cooling performance of the CWCT at an air wet-bulb temperature 0℃, 2℃, and 4℃ is about 47%–63% of the rated operating condition;the optimal operating parameters of these conditions for the CWCT are just the same as those of the rated operating condition in summer. According to the experimental results, some operating advices are given.Closed wet cooling towers(CWCTs) are used widely because of their better water quality and smaller water consumption. However, the operating parameters shown in the technical documents are only for rated conditions in summer, not for any other conditions, especially in low air wet-bulb temperature areas such as those near 0°C. In addition, CWCTs often fail to achieve the designed cooling effect at low air wet-bulb temperatures. A experiment set of CWCT was built, and the performance of the CWCT at low air wet-bulb temperature near 0°C was investigated. The impact of the operating parameters(air flow rate, cooling water flow rate, and spray water flow rate) on the heat and mass transfer performance of the CWCT was measured and analyzed. The results show the cooling performance of the CWCT at an air wet-bulb temperature 0°C, 2°C, and 4°C is about 47%–63% of the rated operating condition; the optimal operating parameters of these conditions for the CWCT are just the same as those of the rated operating condition in summer. According to the experimental results, some operating advices are given.

关 键 词:CLOSED wet COOLING TOWER performance of COOLING TOWER low AIR WET-BULB TEMPERATURE rated operating parameters evaluation index 

分 类 号:TU991.42[建筑科学—市政工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象