检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:高军 马光宇 刘常鹏 张天赋 杨荣强[2] 赵俣 Gao Jun;Ma Guangyu;Liu Changpeng;Zhang Tianfu;Yang Rongqiang;Zhao Yu(Ansteel Iron & Steel Research Institutes,Anshan 114009,Liaoning,China;Cold Rolled Strip Steel Mill of Angang Steel Co.,Ltd.,Anshan 114021,Liaoning,China)
机构地区:[1]鞍钢集团钢铁研究院,辽宁鞍山114009 [2]鞍钢股份有限公司冷轧厂,辽宁鞍山114021
出 处:《鞍钢技术》2019年第5期24-27,34,共5页Angang Technology
摘 要:针对鞍钢冷轧热镀锌线退火炉煤气单耗增加的问题,进行了热工测试和热平衡结果分析,提出了提高无氧化段空气过剩系数、降低辐射管段空气过剩系数、优化辐射管结构和减少炉墙表面散热等节能措施,实施后,镀锌线退火炉煤气单耗由0.955GJ/t降为0.927GJ/t,年节约煤气9800GJ,节能效果显著。In allusion to the problem that the gas consumption for annealing furnace for cold rolled hot-dip galvanizing line in Ansteel went on rising, the thermal testing and thermal balance analysis on gas consumption were carried out. Energy saving measures such as increasing the air excess coefficient in non-oxidation zone, reducing the air excess coefficient in radiant tube zone, optimizing the structure of the radiant tube and decreasing the heat dissipation from the surface of the furnace wall were proposed. After the measures were put into practice, the gas consumption for annealing furnace for galvanizing line was lowered to 0.927 GJ/t from 0.955 GJ/t and the amount of gas saving per year was 9 800 GJ, which meant the energy-saving effect was significant.
分 类 号:TG155[金属学及工艺—热处理]