音叉式石英晶振共振频率对QEPAS传感器性能影响的研究  被引量:1

Impact of Resonance Frequency of Quartz Tuning Fork on QEPAS-Based Sensors

在线阅读下载全文

作  者:李彪[1,2] 董磊 武红鹏[1,2] LI Biao;DONG Lei;WU Hong-peng(State Key Laboratory of Quantum Optics and Quantum Optics Devices,Institute of Laser Spectroscopy,Shanxi University,Taiyuan 030006,China;Collaborative Innovation Center of Extreme Optics,Shanxi University,Taiyuan 030006,China)

机构地区:[1]山西大学激光光谱研究所,量子光学与光量子器件国家重点实验室,山西太原030006 [2]极端光学协同创新中心,山西太原030006

出  处:《光谱学与光谱分析》2019年第10期3056-3060,共5页Spectroscopy and Spectral Analysis

基  金:国家自然科学基金项目(61805132,61622503,61575113);山西省“1331工程”重点学科建设计划经费;山西省中青年拔尖创新人才支持计划;山西省“三晋学者”特聘教授支持计划(2017QNSJXZ-04);2018中央提升武红鹏人才事业启动经费(227545028)资助

摘  要:以标准商用石英音叉(QTF)为测声模块的石英增强光声光谱(QEPAS)技术是近年来发展迅速的一种痕量气体检测技术。标准商用QTF拥有的小体积,高Q值,高共振频率的特性使QEPAS技术具有结构紧凑且对环境噪声免疫的特性。但传统商用QTF狭窄的振臂间距以及较高的共振频率,使其无法在光源光束质量较差或被测气体弛豫率较低的情况下被很好的应用于QEPAS系统。为克服上述难题,非标准商用QTF(f0≠32.7kHz)被设计制作并越来越多的被装配于QEPAS系统中。因此,QTF共振频率对QEPAS系统信噪比的影响需要被详细研究。以水汽为目标气体,采用二次谐波调制解调技术研究了QTF共振频率对基于QEPAS技术传感器性能的影响。实验结果表明,QTF共振频率的变化对QEPAS系统的输出信号及噪声均有显著影响且QTF共振频率与QEPAS系统信噪比之间存在反比关系。上述结论对QEPAS系统中非标准QTF的设计及使用均具有重要的指导价值,对该类传感器的研发及应用意义重大。Quartz-enhanced photoacoustic spectroscopy(QEPAS)based spectrophone has developed rapidly in recent years.With the benefit of a quartz tuning fork(QTF),the QEPAS technique offerscompact structure and low sensitivity to surrounding noise.However,it’s difficult to use the standard QTF for slowly relaxing gas molecule detection as the high resonance frequencyof QTF.And it is a big challenge touse the laser with low beam quality as the excitation light sources of the QEPAS system because the gap size between the prongs of the standard QTF is too narrow.Non-standard QTFs(f 0≠32.768 kHz)have been installed in QEPAS system as acoustic transducer in recent years.Therefore,the influence of the resonance frequencies of QTFs on the QEPAS system performance must be studied in detail.In this paper,the water vapor was used as the target gas and was detected via different QEPAS-based gas sensors in which the four QTFs with different resonance frequencies were installed as the acoustic transducer.The experimental results show that the resonant frequency of the QEPAS acoustic transducer has a significant effect on the signal-to-noise ratio of the QEPAS system.The reported results are extremely useful in the design of the QEPAS spectrophone.

关 键 词:石英增强光声光谱 石英音叉 光学气体传感器 痕量气体检测 

分 类 号:O433.1[机械工程—光学工程]

 