摘 要:医院在设计前期需与院方及各个实验室充分沟通,针对不同科室的不同供排水需求,进行分质分路供水,分类收集、分类处理排水,确保医院给排水的安全可靠。阐述了上海市综合医疗大楼动物实验室、病原病原微生物实验室及其他公共实验室采用二级反渗透/EDI联合制备纯水的工艺,供给满足水质、水量、水压要求的纯水;病原微生物实验室产生的废水,先进行收集、灭活后再排水,保证排水的安全性。In the early stage of hospital water supply and drainage design, it is necessary to fully communicate with the hospital and various laboratories. In order to ensure the safety and reliability of hospital water supply and drainage, water supply should be divided into different grades according to the different water supply and drainage needs of different departments. The article describes the process of preparing pure water by two-stage RO/EDI in animal laboratory, pathogenic microorganism laboratory and other public laboratories of Shanghai comprehesive Medical Building, providing pure water to meet the water quality, water quantity and water pressure;collect and inactivate wastewater from pathogenic microorganism laboratory, and then drain it to ensure the safety of drainage.