检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:汤自强 刘君 王刚 肖海刚 黄万启[2] TANG Ziqiang;LIU Jun;WANG Gang;XIAO Haigang;HUANG Wanqi(Ningxia Jingneng Ningdong Electric Power Co.Ltd,Yinchuan Ningxia 750000,China;Xi’an Thermal Power Research Institute Co.Ltd,Xi’an Shaanxi 710000,China)
机构地区:[1]宁夏京能宁东发电有限责任公司,宁夏银川750000 [2]西安热工研究院有限公司,陕西西安710000
出 处:《宁夏电力》2019年第4期61-66,共6页Ningxia Electric Power
摘 要:SCAL型间冷系统的循环废水中含有大量铁铝腐蚀产物,根据间冷循环水的水质特点,通过理论分析拟定了回收方案,通过工业实验对其进行了验证。结果表明,实施回收前需要对废水的温度、pH值、浊度和铁铝含量进行测定,当循环废水的水质指标不能满足水处理设备进水要求时,需要按照一定的比例将间冷循环废水和厂区生水在生水箱中混合后再进行回收处理。Comparing with raw water,the circulating water in SCAL indirect air-cooling system contained much corrosion products of steel and aluminum.By theoretical analysis the recovery scheme was made up according to the water quality of indirect air-cooling circulating water.Then it is verified by the industry tests.The results indicates the temperature,pH,turbidity and content of Fe and AL of waste water should be measured before recycling.In case some water quality indexes of waste water could not satisfy the water inlet requirements of watertreatment equipment,mixing the raw water and waste water by a ratio could solve this problem.
关 键 词:SCAL型间接空冷系统 废水回收 水处理