X射线荧光元素录井仪测量精度分析效果比对  被引量:7

Comparison of measuring accuracy analysis results of X-ray fluorescence element logging instrument

在线阅读下载全文

作  者:唐诚 王志战[2] 刘长富 廖震 施强 王崇敬 梁波 Tang Cheng;Wang Zhizhan;Liu Changfu;Liao Zhen;Shi Qiang;Wang Chongjing;Liang Bo

机构地区:[1]中石化西南石油工程有限公司地质录井分公司 [2]中国石化石油工程技术研究院测录井研究所 [3]中石化西南石油局有限公司资产经营管理部

出  处:《录井工程》2019年第3期117-123,189,共8页Mud Logging Engineering

基  金:中石化科技部项目“基于XRF的页岩地层多参数实时求取方法及应用”(编号:P17014-9)

摘  要:X射线荧光元素录井技术已经得到了广泛的应用,但由于仪器的型号多,不同型号仪器的测量结果有一定差异,导致油田建设方对分析结果产生质疑,故以实验室级别的波长色散型仪器分析结果为标准,对比4种能量色散型仪器的分析效果。仪器对比表明,不同仪器的测量结果有差异,但对主要元素而言,Mg、Al、Ca、Si等元素的测量误差相对较低或误差具有明显的一致性,测量误差变化趋势一致,测量结果能反映地层的真实变化趋势。根据对比情况,分析出现测量误差的原因主要有低原子序数元素测量精度不高,低含量元素的测量误差较大等,因而有必要开展针对性的装备技术研发,同时建议根据不同地层的测量需求,制定具有针对性的精细标定与校准规范,进一步发挥好元素录井的作用。X-ray fluorescence element logging technology has been widely used.However,due to the various types of instruments,the measurement results of different types of instruments have certain differences,which leads to the oilfield construction party questioning the analysis results.Therefore,the analytical results of the laboratory-level wavelength dispersion type instruments are taken as standards,and the analysis results of four kinds of energy dispersion instruments are compared.The comparison of instruments shows that the measurement results of different instruments are different.However,for the main elements,the measurement errors of elements Mg,Al,Ca,Si and other elements are relatively low or have obvious consistency,the variation trend of measurement error is accordant and the measurement results can reflect the true trend of formation.According to the comparison,the reasons for the measurement error are mainly low measurement accuracy of low atomic number elements and the large measurement errors of low content elements.Therefore it is necessary to carry out targeted equipment technology research and development.At the same time,it is suggested to develop targeted fine calibration and calibration specifications according to the measurement requirements of different strata,so as to further play the role of element logging.

关 键 词:录井 XRF元素录井 仪器对比 误差分析 

分 类 号:TE132.1[石油与天然气工程—油气勘探]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象