摘  要:背景:目前对下肢血管疾病的研究趋于热门,在以大型动物为研究平台的实验中,需要对动物下肢血管进行形态及密度的检测,以研究和验证干预措施的有效性,且这种检测方法需要较高的可行性及可重复性。目的:探讨数字减影血管造影技术应用于犬类动物模型下肢动脉造影中的可行性、影响因素及应用价值。方法:6只比格犬经麻醉后固定于工作床,于犬大腿上段股动脉搏动明显处,采用留置针进行经皮股动脉顺行穿刺,人工推注对比剂,采用数字减影血管造影步进技术采集造影图像,对图像效果及影响因素进行分析。结果与结论:(1)所有6只比格犬双后肢最终动脉造影图像显示清晰,能分辨细小血管分支,无伪影;(2)其中第1只犬在初次造影时因对比剂刺激导致肢体抖动,图像效果欠佳,经固定肢体及稀释对比剂后再次造影得到了清晰图像;(3)提示采用数字减影血管造影技术进行犬类动物模型动脉造影可以清晰显示血管形态及密度,操作简单、重复性好,对模拟肢体缺血的动物模型研究具有重要意义。BACKGROUND:The research on lower extremity vascular disease is becoming popular.In the experiment of large animals as research platform,it is necessary to detect the shape and density of lower extremity vascular in order to study and verify the effectiveness of intervention measures,and this detection method needs high feasibility and repeatability.OBJECTIVE:To investigate the feasibility,influencing factors and application value of digital subtraction angiography in lower limb arteriography of a canine animal model.METHODS:Six Beagle dogs were fixed on the working bed after anesthesia and punctured percutaneously through the femoral artery with an indwelling needle.Contrast agent was injected artificially.Digital subtraction angiography bolus chase technology was used to collect contrast images.The image effect and influencing factors were analyzed.RESULTS AND CONCLUSION:(1)The final arteriography images of all six Beagle dogs’hind limbs were clear,and the branches of small vessels could be distinguished without artifacts.(2)The first beagle shook when encountering contrast agent stimulation during the initial angiography,resulting in poor image effect.After fixing the limbs and diluting the contrast agent,the clear images were obtained by re-angiography.(3)These results indicate that arteriography using digital subtraction angiography can clearly reveal the shape and density of blood vessels in canine animal models.It is simple and reproducible,and is of great significance for research on animal models of limb ischemia.

关 键 词:数字减影血管造影 动物模型  大型动物 下肢缺血 血管形态 血管密度 

分 类 号:R459.9[医药卫生—治疗学] R318[医药卫生—临床医学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象