摘 要:目的设计出符合规范及临床要求的集中供液系统,提高透析治疗质量。方法遵循国家及行业标准的技术细节,结合医院的实际情况进行设计;制定好流程、规范、应急预案、维护保养等细则,医、护、工程师、工人共同参与,保障集中供液系统的稳定供液,保障透析治疗过程的安全用液。结果血透室成功安装了集中供液系统,并稳定使用了4年,对微生物、内毒素、生化等进行了系统的监控。相对于传统桶装成品供液模式,集中供液系统使护士操作更加方便,血透机电导率参数更加稳定,病人治疗更加安全。结论规范的集中供液系统使成本降低、操作便利、设备稳定、疗效提高,代表着行业发展的方向。Objective To design a centralized dialysate supply system that meets the standard and clinical requirements,and improve the quality of dialysis treatment.Methods Following the technical details of the national and industrial standards,the centralized dialysate supply system was designed according to the actual situation of our hospital.We formulated procedures,norms,emergency plans,maintenance of the centralized dialysate supply system to ensure the stable supply of the centralized dialysate supply system and the safe use of dialysate during treatment with the cooperation of doctors,nurses,engineers and workers.Results The centralized dialysate supply system was installed successfully and used stably for 4 years in our hemodialysis room.The microorganism,endotoxin,and biochemistry parameters were monitored systematically.Compared with the traditional barreled fluid supply model,the centralized fluid supply system were more convenient for nurses,more stable,and more safe for patients.Conclusion The standard use of the centralized dialysate supply system has reduced the cost,made the operation convenient,stabilized the hemodialysis machine and improved the curative effect,which represents the direction of the industry development.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15