检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张盼盼[1] 牛智领[1] 闫斌[1] 刘素梅[1] 葛晓航[1] 彭霈 刘乐喜[1] 刘远洪[1] Zhang Panpan;Niu Zhiling;Yan Bin;Liu Sumei;Ge Xiaohang;Peng Pei;Liu Lexi;Liu Yuanhong(Third Division,Department of Neurology,Puyang People’s Hospital,Puyang,Henan 457000,China)
机构地区:[1]河南省濮阳市人民医院神经内科三病区,457000
出 处:《中华生物医学工程杂志》2019年第4期411-414,共4页Chinese Journal of Biomedical Engineering
摘 要:目的研究磁敏感加权成像(SWI)在大鼠缺血性卒中缺血半暗带中的预测价值.方法将30只SD大鼠参照改良Longa法制备脑动脉缺血再灌注模型.造模成功后,采用磁共振机器进行扫描,分别扫描其扩散加权成像(DWI)、SWI和磁共振灌注造影成像(PWI)序列,采用2,3,5-三苯基氯化四氮唑(TTC)法检测脑组织梗死面积;采用Person相关性分析SWI与PWI检测之间的相关性,采用Kappa一致性检验SWI检测缺血半暗带的准确率、灵敏度、特异性、阳性预测、阴性预测和Kappa值;采用受试者工作特征(ROC)曲线分析SWI对缺血半暗带的预测价值,曲线下面积(AUC)表示诊断的准确度.结果SWI与PWI的脑组织ASPECTS评分和DWI不匹配区域呈显著正相关关系(r=0.795,P=0.000;r=0.812,P=0.000);采用一致性分析,SWI诊断缺血半暗带的灵敏度为92.00%,特异度为100.00%,准确率为93.33%,阳性预测值为100.00%,阴性预测值为71.43%,Kappa值为0.793;ROC分析显示,SWI诊断大鼠缺血性卒中缺血半暗带的AUC为0.933.结论SWI对大鼠缺血性卒中的缺血半暗带具有较高的预测价值.Objective To evaluate the predictive value of susceptibility weighted imaging(SWI)for ischemic penumbra in rats with ischemic stroke.Methods Thirty SD rats were used for modeling ofcerebral artery ischemia reperfusion via modified Longa method.After successful modeling,the rats underwentmagnetic resonanceexaminationfordiffusion-weighted imaging(DWI),SWI,and perfusion-weighted imaging(PWI)sequences.The 2,3 and 5-triphenyltetrazolium chloride(TTC)method was usedto detect the infarct size of brain tissues.The correlation between SWI and PWI was analyzed by Pearson correlation analysis.Kappa consistency test was performed to detect accuracy,sensitivity,specificity,positive predictive,negative predictive and Kappa values of SWI for detecting ischemic penumbra.The receiver operating characteristic(ROC)curve was generated to analyze predictive value of SWI for ischemic penumbra.The area under the curve(AUC)was calculated toevaluate the diagnosticaccuracy.Results The brain tissues ASPECTS scores of SWI and PWI were significantly positively correlated with DWI-unmatched areas(r=0.795,P=0.000.r=0.812,P=0.000).Kappaconsistency analysis showed that the accuracy,sensitivity,specificity,positive predictive,negative predictive and Kappa values of SWI for diagnosis of ischemic penumbra were 92.00%,100.00%,93.33%,100.00%,71.43% and 0.793,respectively.ROC analysis showed that AUC of SWI for diagnosis of ischemia penumbra inischemic stroke rats was 0.933.Conclusion Relatively high predictive value ispossible with SWI for ischemic penumbra in ischemic stroke rats.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145