检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘慧媛 肖繁 张哲[3] 尹项根[3] 刘玮 LIU Huiyuan;XIAO Fan;ZHANG Zhe;YIN Xianggen;LIU Wei(Yangjiang Power Supply Bureau of Guangdong Power Grid Co.,Ltd.,Yangjiang 529500,China;Electric Power Research Institute of State Grid Hubei Power Grid Co.,Ltd.,Wuhan 430077,China;State Key Laboratory of Advanced Electromagnetic Engineering and Technology(Huazhong University of Science and Technology),Wuhan 430074,China;Guangdong Power Grid Co.,Ltd.,Guangzhou 510630,China)
机构地区:[1]广东电网有限责任公司阳江供电局,广东省阳江市529500 [2]国网湖北省电力有限公司电力科学研究院,湖北省武汉市430077 [3]强电磁与新技术国家重点实验室(华中科技大学),湖北省武汉市430074 [4]广东电网有限责任公司,广东省广州市510630
出 处:《电力系统自动化》2019年第21期177-186,共10页Automation of Electric Power Systems
基 金:国家重点研发计划资助项目(2016YFB0900600)~~
摘 要:当新能源机组接入三相不平衡的配电网后,由于配电网不平衡元件在正、负、零序条件下难以解耦,将使得以传统对称分量法为基础的电网短路电流存在难以准确计算等问题,需要以相分量故障分析方法为基础进行计算。同时,新能源电源在电网故障条件下将进行低电压穿越运行,受其接入方式、低电压穿越控制策略及机组Crowbar保护等因素的影响,其短路电流特性将不同于传统同步电机,需要建立不同类型的新能源电源短路计算相分量模型。因此,文中首先根据不同类型新能源机组的低电压穿越控制策略综合分析了现有新能源电源等值计算模型,并建立了相应的短路计算相分量模型,然后基于传统相分量故障分析法,根据故障条件建立故障后的相分量导纳矩阵和电压方程,进而提出了含不同类型新能源接入不平衡配电网的短路计算方法。最后,通过仿真案例对所提方法的有效性进行验证。When renewable energy units are connected to three-phase unbalanced distribution network, it is difficult to decouple unbalanced components of distribution network under positive, negative and zero-sequence conditions, which makes it difficult to accurately calculate the short-circuit current of power network based on traditional symmetric component method. It is necessary to calculate the short-circuit current based on phase component fault analysis method. At the same time, the renewable energy source will be operated at low voltage ride through(LVRT) mode under the condition of power grid fault. Influenced by its access mode, LVRT control strategy and Crowbar protection, the short-circuit current characteristics of the renewable energy source will be different from that of the traditional synchronous motor. It is necessary to establish phase component models for short-circuit calculation of different types of renewable energy sources. Therefore, this paper first synthetically analyses the existing equivalent calculation models of renewable energy sources according to the LVRT control strategies for different types of renewable energy units, and establishes the corresponding phase component model for short-circuit calculation. Then, based on the traditional phase component fault analysis method, the phase component admittance matrix and the voltage equation after fault are established according to the fault conditions. A short-circuit calculation method for unbalanced distribution networks with different types of renewable energy is proposed. Finally, the effectiveness of the proposed method is verified by a simulation case.
关 键 词:新能源电源 风电机组 光伏发电 不平衡配电网 短路计算 相分量
分 类 号:TM7[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.145.165.235