检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:朱文博 朱伟 丁金东 马小强 姚红 张有明[1] 林奇[1] 魏太保[1] Zhu Wenbo;Zhu Wei;Ding Jindong;Ma Xiaoqiang;Yao Hong;Zhang Youming;Lin Qi;Wei Taibao(Key Laboratory of Polymer Materials of Gansu Province,College of Chemistry and Chemical Engineering,Northwest Normal University,Lanzhou 730070)
机构地区:[1]西北师范大学化学化工学院生态环境相关高分子材料教育部重点实验室甘肃省高分子材料重点实验室
出 处:《有机化学》2019年第10期2829-2834,共6页Chinese Journal of Organic Chemistry
基 金:Project supported by the National Natural Science Foundation of China(Nos.21662031,21661028,21574104,21262032)~~
摘 要:合成了一种新型的基于5-(3-硝基苯基)-呋喃-2-甲醛功能化的巴比妥酸衍生物传感器QS.通过1H NMR,13C NMR,MS等方法对QS进行了表征.QS的荧光光谱结果表明QS的二甲亚砜(DMSO)溶液在498 nm有最大荧光发射,在365 nm紫外灯下照射发出绿色荧光.QS对H^g2+和Fe^3+的水溶液有不同的荧光检测能力,Hg^2+能使探针QS的荧光增强为橙色,Fe^3+使其荧光猝灭,实现了实时检测.传感器QS对Hg^2+和Fe^3+的荧光检测限分别为3.25×10^-8和4.0×10^-8 mol·L^-1.根据Job曲线和质谱研究得到QS与汞离子和铁离子化学计量比均为1∶1,提出了QS与Hg^2+和Fe^3+的可能结合模式.加入H2PO4^-能使含有Fe^3+的QS溶液(QS-Fe)荧光恢复,可用于Fe^3+的循环检测.此外,固体QS可从水溶液中吸附Hg^2+和Fe^3+(吸附率分别为92.0%和91.8%),具有较好的吸附能力.A novel fluorescent sensor based on 5-(3-nitrophenyl)-furan-2-carbaldehyde functionalized barbituric acid derivative(QS)was successfully synthesized.QS was characterized by 1H NMR,13C NMR and MS.The maximum fluorescence emission wavelength of QS in dimethyl sulfoxide(DMSO)solution was determined to be 498 nm and green fluorescence was emitted under 365 nm ultraviolet lamp.QS showed different fluorescence identification ability for aqueous solution of Hg^2+ and Fe^3+.Hg^2+ can enhance the fluorescence of probe QS to orange,and Fe^3+ quenches its fluorescence,thus realizing realtime detection.The limits of detection of QS for Hg^2+ and Fe^3+ are 3.25×10^-8 and 4.0×10^-8 mol·L^-1,respectively.The fluorescence measurements and MS studies suggest that the binding stoichiometry ratios of QS with Hg^2+ and Fe^3+ are recognized as 1∶1,respectively.The possible modes of QS with Hg^2+ and Fe^3+ are proposed.The addition of H2PO4^- caused the fluorescence of QS-Fe recover,indicating that QS can be used for cyclic detection of Fe^3+.More importantly,the separation percentages of the solid QS for Hg^2+ and Fe^3+ are 92.0% and 91.8% in aqueous solution,respectively,indicating that it has excellent ingestion capacity.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.115.20