检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:胡念 庄盈笑 HU Nian;ZHUANG Yingxiao(Shanghai Testing Standard of Textile Group Co.Ltd.,Shanghai 200082,China)
机构地区:[1]上海纺织集团检测标准有限公司
出 处:《纺织检测与标准》2019年第5期14-17,共4页Textile Testing and Standard
摘 要:锦纶6切片在特制的索氏萃取器中经热水萃取后可在折光仪上测定萃取液的折光率,从而可计算得到热水可萃取物的含量。分析了PA6切片质量和萃取时间对热水可萃取物含量的影响。结果表明,PA6切片经热水萃取时,当切片质量为20g、萃取8h时可获得较好的萃取效果,且测试结果准确。After hot water extraction in a special Soxhlet extractor,the refractive index of polyamide 6 section could be determined on a refractometer,and the content of hot water extractable could be calculated.The effects of PA6 slice quality and extraction time on the mass fraction of hot water extractable matter were analyzed.The re sults showed that when PA6 sections were extracted by hot water,better extraction effect could be obtained with sec tions 20 g and extraction 8 h,and the test results were accurate.
分 类 号:TS107[轻工技术与工程—纺织工程]