检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张健平[1] 王聪 刘秋霞 王勇[1] 张耀洁 ZHANG Jianping;WANG Cong;LIU Qiuxia;WANG Yong;ZHANG Yaojie(Key Laboratory of Testing Technology for Manufacturing Process of Ministry of Education,Southwest University of Science and Technology,Mianyang Sichuang 621010,China)
机构地区:[1]西南科技大学制造过程测试技术教育部重点实验室
出 处:《机床与液压》2019年第22期133-139,共7页Machine Tool & Hydraulics
基 金:国家自然科学基金青年科学基金项目(51308480);四川省教育厅一般项目(16ZB0136);西南科技大学博士研究基金项目(17ZX7125)
摘 要:为了使梭式止回阀在中压大口径管道输送领域得到更好的利用,利用ANSYS15.0中的流体动力学分析模块Fluent,基于κ-ε标准湍流模型,采用一阶迎风格式的离散方法和压力-速度耦合的Simple算法对梭式止回阀流动特性进行数值摸拟。通过与传统常用的升降式止回阀对比,模拟分析了两种止回阀开启过程中速度、压力和流阻系数变化规律和分布情况。结果表明:相对于升降式止回阀,流体在梭式止回阀中速度和压力分布更均匀,具有良好的对称性,梭式止回阀的速度梯度明显减少,其最大速度约为升降式止回阀的0.45倍;梭式止回阀的流阻系数明显比升降式止回阀的小,当开度为5%~15%时,梭式止回阀流阻系数下降显著,尤其是在开度为5%时,其相对降低量为88.4%,比升降式止回阀多18.9%。因此,梭式止回阀在整个开启过程中不会产生较大的冲击,降低了水流冲击阀瓣的噪声,提高了止回阀的防水锤特性。In order to utilize the shuttle-type check valve in the field of medium-pressure&large-diameter pipeline,the flow characteristics of shuttle-type check valve was simulated by using ANSYS15.0 Fluent software.Based onκ-εstandard turbulence model,the discrete method of first order windward format and Simple algorithm were used to make simulation.Through comparing with traditional lift check valve,the variation and distribution of velocity,pressure and flow resistance coefficient of the two check valves were simulated and analyzed in the process of opening.The results show that the fluid velocity and pressure distribution of the shuttle-type check valve are more uniform,better symmetry,and the speed gradient is significantly reduced.Maximum speed of the shuttle-type check valve is about 0.45 times the lift check valve.Flow resistance coefficient of the shuttle-type check valve is obviously smaller than the lift check valve.And the flow resistance coefficient of the shuttle-type check valve decreases significantly on 5%~15%opening.Especially,the relative reduction of the flow resistance coefficient is 88.4%,and flow resistance coefficient of the shuttle-typecheck valve is 18.9%higher than the lift check valve on 5%opening.Therefore,the shuttle-type check valve doesn’t have a large impact during the whole opening process,which reduces the noise of the water flow impact disc and improves the anti-water hammer characteristics.
分 类 号:TH137.52[机械工程—机械制造及自动化] TH136
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.62