专用电机定子绝缘性能可靠性试验及评估  

Reliability test and evaluation for insulation performance of motor stators

在线阅读下载全文

作  者:钱毅[1,2] 张宁[2] Qian Yi;Zhang Ning(School of Mechanical Engineering,Hebei University of Technology,Tianjin 300401,China;Science and Technology on Particle Transport and Separation Laboratory,Tianjin Institute of Physical and Chemical Engineering,Tianjin 300180,China)

机构地区:[1]河北工业大学机械学院,天津300401 [2]核工业理化工程研究院粒子富集与输运重点实验室,天津300180

出  处:《质量与可靠性》2019年第6期13-16,21,共5页Quality and Reliability

摘  要:在机群调节过程中,由于存在操作过电压情况,使得旋转机械专用电机定子有可能出现匝间短路的问题,甚至会引发机器失效,导致严重的经济损失。在建立专用电机定子绝缘材料耐冲击电压可靠性模型的基础上,开展定时截尾寿命试验,并基于配分布曲线法处理无失效试验数据,得到了旋转机械专用电机定子绝缘性能可靠性指标,为使用方判定电机是否需改进设计提供可靠性方面的依据。In the process of cluster adjustment, due to the existence of operation overvoltage, the problem of interterm short circuit of the motor stator is emerged, which results in damages of motor performance, failures of machine and economic losses. This paper introduces the reliability model of withstand impulse voltage of insulation of motor stators. Time censored of life test is carried out. Based on distribution curve method, zero-failure data are processed, and the reliability index of insulation performance of motor stator is obtained, which is provided to the users for the proposal of motor improvements.

关 键 词:专用电机 绝缘材料 寿命试验 配分布曲线法 

分 类 号:TP3[自动化与计算机技术—计算机科学与技术]

 