作 者:张会建[1] 袁堃[1] 董元宏[1] 符进 ZHANG Huijian;YUAN Kun;DONG Yuanhong;FU Jin(State Key Laboratory of Road Engineering Safety and Health in Cold and High-altitude Regions, CCCC First Highway Consultants Co., Ltd., Xi'an 710065, China)
机构地区:[1]中交第一公路勘察设计研究院有限公司高寒高海拔地区道路工程安全与健康国家重点实验室
出 处:《路基工程》2019年第6期6-12,共7页Subgrade Engineering
基 金:陕西省科技新星项目(2017KJXX-25);陕西省科技新星项目(2017KJXX-26)
摘 要:为研究宽幅XPS保温板路基地温调控效果,对共和至玉树高速公路21.5 m幅宽的XPS保温板路基和幅宽13.5 m热棒-XPS保温板复合路基试验路的冻土地温进行了长期系统的监测。结果表明:宽幅XPS保温板路基冻土上限年下降速率、冻土上限位置升温速率和吸热量分别为宽幅普通路基的76 %,62 %,55 %,然而宽幅XPS保温板路基下伏多年冻土仍以较快的速率发生退化,上限下降速率达到0.5 m/a;铺设黑色路面后,宽幅XPS保温板路基和宽幅普通路基吸热量均增大约1倍;和单一的XPS保温板隔热措施相比,热棒-XPS保温板复合路基对路面下2~5 m范围内土层地温产生调控效果,可有效改善采用单一XPS保温板工程措施的被动吸热状态,提高冻土路基热稳定性。To study the regulation effect of ground temperature in large-width subgrade with XPS insulation board, long-term and systematic supervision on the frozen ground temperature was carried out along Gonghe—Yushu Highway in the test section which has the subgrade 21.5 m in width with XPS insulation board and the test section which has the composite subgrade 13.5 m in width with thermosyphon and XPS insulation board. The result shows that, as to large-width subgrade with XPS insulation board, the annual descending rate of the permafrost table, the rate of temperature rise and the heat absorption at the position of permafrost table were 76 %, 62 % and 55 % of that of the ordinary-width subgrade, respectively, however, the permafrost underlying the large-width subgrade with XPS insulation board degrades at a relatively fast speed with the descending rate up to 0.5 m/a;after black pavement placed, both the large-width subgrade with XPS insulation board and the ordinary-width subgrade have the heat absorption doubled approximately;compared to the measure of XPS insulation board only, the composite subgrade with thermosyphon and XPS insulation board may regulate the ground temperature within 2~5 m depth of soil thereunder, improve the passive state of heat absorption and enhance the thermal stability of permafrost subgrade.
关 键 词:多年冻土区 高速公路 宽幅XPS保温板路基 传热特征 地温 热量收支
分 类 号:U416.1+68[交通运输工程—道路与铁道工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.177