检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:于樱迎 唐瑾晨[1] 胡学功[1,2] YU Yingying;TANG Jinchen;HU Xuegong(Institute of Engineering Thermophysics,Chinese Academy of Sciences,Beijing 100190,China;University of Chinese Academy of Sciences,Beijing 100049,China)
机构地区:[1]中国科学院工程热物理研究所,北京100190 [2]中国科学院大学,北京100049
出 处:《化工进展》2020年第1期26-33,共8页Chemical Industry and Engineering Progress
基 金:国家重点研发计划(2017YFB0403200)
摘 要:微槽群在热流密度较大时会达到其毛细极限,可通过主动换热方式之一--电水动力学效应对其进行强化。本文为了研究电场对微槽群表面润湿特性和温度分布的影响,采用平板电极提供电场,蒸馏水作为工质,使用高速相机拍摄微槽内液体润湿长度,测量误差为2.97%~7.46%;使用红外热像仪拍摄电场作用下微槽群表面温度分布,测量误差为2.1%~2.39%。热流密度测量误差范围是9.66%~11.11%。结果表明:电场通过驱动微槽内流体向加热区域流动而提升其润湿性能,且较低热流密度下提升更好。因润湿性能的提升,微槽表面温度得以下降。随着电场增强,微槽横向温度分布的"波峰"、"波谷"差别加大,微槽纵向温度明显降低。当热流密度加大时,温降更为显著,1.4W/cm^2热流密度、6kV电压下温降可达到30℃以上。温降的增加反映了电场对微槽的强化润湿进一步提升了微槽换热性能,且电场对较高热流情形下的微槽换热有着更为显著的强化效果。The capillary limit of the microgrooves is reached when the capillary pumping is not capable to overcome the pressure drops due to high heat flux. One of the active techniques, the electrohydrodynamic effect(EHD) can be used to deal with this situation and improve the thermal performance of microgrooves.To study the electric field effects on the microgroove wettability and temperature, a planar electrode pair was used to generate electric fields and the distilled water was used as working fluid. Using a high speed camera to record the wetting length, the measurement deviation is 2.97%~7.46%, and using an infrared thermal imager to record the temperature distribution, the deviation is 2.1%~2.39%. The heat loss deviation is 9.66%~11.11%. The results show that the electric field can enhance the microgrooves wettability by driving liquid towards the heated region. The enhancement is more distinguished when the heat flux is smaller. In addition, attributed to the enhanced wettability, the microgroove temperature is reduced. There exist "peak" and "valley" in the transverse temperature distribution, and the disparity between the "peak" and "valley" increases as the electric field increases. The longitudinal temperature decreases pronouncedly with the electric field increment. Higher heat flux leads to a larger temperature decline, which could reach 30℃ with 6 kV under 1.4 W/cm^2. The increased temperature decline indicates that the electric fields further improve the microgroove heat-transfer performance by enhancing the microgroove wettability, especially for higher heat flux conditions.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229