Good accuracy of the alpha-defensin lateral flow test for hip periprosthetic joint infection: A pilot study in a retrospective cohort of 52 patients  

Good accuracy of the alpha-defensin lateral flow test for hip periprosthetic joint infection: A pilot study in a retrospective cohort of 52 patients

在线阅读下载全文

作  者:Jesse WP Kuiper Pieter Pander Stan J Vos 

机构地区:[1]Department of Orthopedic Surgery,Noordwest Ziekenhuisgroep,Alkmaar 1815 JD,Netherlands [2]Centre for Orthopedic Research Alkmaar,Noordwest Ziekenhuisgroep,Alkmaar 1815 JD,Netherlands

出  处:《World Journal of Orthopedics》2020年第1期36-46,共11页世界骨科杂志(英文版)

摘  要:BACKGROUND The alpha-defensin lateral flow(ADLF)test is a new diagnostic tool for periprosthetic joint infection(PJI).Test accuracy for combined cohorts of hip and knee PJI has been reported to be good.AIM To assess the accuracy of the ADLF test for hip PJI,and to compare three different diagnostic criteria for PJI.METHODS A cohort of 52 patients was identified,with a painful or poor-functioning total hip-or hemi-arthroplasty,that underwent aspiration and a subsequent ADLF test.PJI was diagnosed with Musculoskeletal Infection Society(MSIS)criteria,and sensitivity,specificity,overall accuracy,positive predictive value and negative predictive value were calculated.Furthermore,test specifics were compared with the European Bone and Joint Infection Society(EBJIS)and 2018 International Consensus Meeting(ICM)criteria for PJI.RESULTS Using MSIS criteria,sensitivity was 100%(CI:54%-100%)and specificity was 89%(CI:76%-96%).Six true positives and 5 false positives were found,including one case of metallosis.Using EBJIS criteria,more PJIs were found(11 vs 6),sensitivity was lower(71%,CI:42%-92%)and specificity was higher(97%,CI:86%-100%),with 4 false negatives and one false positive result.Using 2018 ICM criteria,sensitivity was 91%(62%-100%)and specificity 100%(91%-100%).The results in this cohort are comparable to previous studies.CONCLUSION Overall test accuracy of the ADLF test was good in this cohort,with a sensitivity of 100%and specificity of 89%.Using different PJI definition criteria,sensitivity and specificity changed slightly but overall accuracy remained around 90%.Using the ADLF test in metallosis cases can result in false positive results and should be performed with caution.BACKGROUND The alpha-defensin lateral flow(ADLF) test is a new diagnostic tool for periprosthetic joint infection(PJI). Test accuracy for combined cohorts of hip and knee PJI has been reported to be good.AIM To assess the accuracy of the ADLF test for hip PJI, and to compare three different diagnostic criteria for PJI.METHODS A cohort of 52 patients was identified, with a painful or poorly functioning total hip-or hemi-arthroplasty, that underwent aspiration and a subsequent ADLF test. PJI was diagnosed with Musculoskeletal Infection Society(MSIS) criteria,and sensitivity, specificity, overall accuracy, positive predictive value and negative predictive value were calculated. Furthermore, test specifics were compared with the European Bone and Joint Infection Society(EBJIS) and 2018 International Consensus Meeting(ICM) criteria for PJI.RESULTS Using MSIS criteria, sensitivity was 100%(CI: 54%-100%) and specificity was 89%(CI: 76%-96%). Six true positives and 5 false positives were found, including one case of metallosis. Using EBJIS criteria, more PJIs were found(11 vs 6), sensitivity was lower(71%, CI: 42%-92%) and specificity was higher(97%, CI: 86%-100%),with 4 false negatives and one false positive result. Using 2018 ICM criteria,sensitivity was 91%(62%-100%) and specificity 100%(91%-100%). The results in this cohort are comparable to previous studies.CONCLUSION Overall test accuracy of the ADLF test was good in this cohort, with a sensitivity of 100% and specificity of 89%. Using different PJI definition criteria, sensitivity and specificity changed slightly but overall accuracy remained around 90%.Using the ADLF test in metallosis cases can result in false positive results and should be performed with caution.

关 键 词:PERIPROSTHETIC ARTHROPLASTY REPLACEMENT HIP Infection Periprosthetic joint infection Alpha-defensin Synovasure 

分 类 号:R68[医药卫生—骨科学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象