矿用隔爆型移动变电站的维护与故障处理  被引量:7

Maintenance and fault handling of mine explosion-proof mobile substation

在线阅读下载全文

作  者:吕耀民 LYU Yao-min(Tongchuan Yaozhou Xiufanggou Coal Mine,Tongchuan 727100,China)

机构地区:[1]铜川市耀州区秀房沟煤矿

出  处:《陕西煤炭》2020年第1期189-191,共3页Shaanxi Coal

摘  要:保证矿用隔爆型移动变电站的安全可靠运行,已成为煤矿供电安全管理的重要工作内容。结合矿用隔爆型移动变电站在煤矿安全生产中的实际应用情况,对移动变电站的基本特征、工作原理、操作维护方法等方面存在的问题进行常见故障分析,并提出相应的解决措施;在解决故障的同时,对操作过程进行了优化,使之更加安全规范。分析认为,熟悉设备基本性能,提高快速排除各种故障的技能,可以为煤矿供电系统的安全可靠提供保障。The safety and reliable operation of mine flameproof mobile substation is an important work of coal mine power supply safety management.Combined with the actual safety production condition in coal mine,the common faults were analyzed from the basic characteristics,working principles,operation and maintenance methods of mobile substation,and its solutions were put forward.At the same time,by optimizing the operation process of mobile substation,the safety was improved.The analysis shows that familiar with the basic performance of the equipment and improving the skills of quick troubleshooting can provide guarantee for the safety and reliability of the coal mine power supply system.

关 键 词:移动变电站 使用操作 日常维护 故障处理 

分 类 号:TD611.2[矿业工程—矿山机电]

 