作 者:王瑞欣 郭亚军[1] 屈鑫鑫 桂淼 毕勤成[2] 高彬 WANG Rui-xin;GUO Ya-jun;QU Xin-xin;GUI Miao;BI Qin-cheng;GAO Bin(School of Building Services Science and Engineering,Xi’an University of Architecture and Technology,Xi’an 710055,China;State Key Laboratory of Multiphase Flour in Power Engineering,Xi'an Jiaotong University,Xi'an 710049,China;State Power Investment Corporation Research Institute,Beijing 102209,China)
机构地区:[1]西安建筑科技大学建筑设备科学与工程学院,陕西西安710055 [2]西安交通大学动力工程多相流国家重点实验室,陕西西安710049 [3]国家电投集团科学技术研究院有限公司,北京102209
出 处:《推进技术》2019年第12期2708-2714,共7页Journal of Propulsion Technology
基 金:国家自然科学基金(51776167);国家科技重大专项基金(2015ZX06002003)
摘 要:管内流态畸变对压差式流量计的测量精度有较大影响。在流量计的上游安装流动调整器,可以达到改善甚至消除流态畸变、提高测量精度的目的。为了研究流动调整器的整流效果及性能,选取竖直双弯头(90°布置)和半开阀门(50%开度)两种涡发生器来产生流态畸变,采用PIV测速技术,对管束式流动调整器、AMCA调整器和Zanker流动调整器三种流动调整器的整流效果进行实验研究。研究结果表明,相较于无流动调整器情况,三种流动调整器均能明显起到改善流态畸变的作用。其中管束式流动调整器和AMCA调整器可以有效地消除径向速度波动和漩涡流动,而Zanker流动调整器消除速度不对称分布的能力最强,同时带来的压力损失也最大。The flow distortion in tube has a great impact on the measurement accuracy of the differential pressure flowmeter.A flow conditioner,placed upstream of the flowmeter,can reduce or completely eliminate this flow distortion in practical applications and improve the measurement accuracy of the flowmeter significantly.In this paper,in order to research the rectification effect and performance of the flow conditioners,the performance of three flow conditioners,i.e.tube bundle flow conditioner,AMCA flow conditioner and Zanker flow conditioner,was experimentally studied by advanced PIV technology.Two vortex generators,i.e.90°configurated double bends and 50%opening value,were selected to produce the flow distortion.The results showed that the flow distortion could be significantly reduced with flow conditioners installed.Tube bundle flow conditioner and AMCA flow conditioner had obvious effects on eliminating the radial velocity fluctuation and vortex flow.Meanwhile,Zanker flow conditioner was found to perform best on offsetting the asymmetrical velocity distribution,while the maximum pressure drop was caused simultaneously.
分 类 号:TH814[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.153