检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:崔朝臣 刘慧[1] 李茂生 刘亚红[1] Cui Chaochen;Liu Hui;Li Maosheng;Liu Yahong(Luoyang Branch Co.,SINOPEC,Luoyang He′nan 471012)
机构地区:[1]中国石化洛阳分公司
出 处:《齐鲁石油化工》2019年第4期308-311,共4页Qilu Petrochemical Technology
摘 要:采用微库仑法测定轻石脑油中氯含量,考察了微库仑分析仪的操作参数对测定结果的影响。WK-2D型微库仑分析仪的较佳工作条件为:偏压250~260 mV,积分电阻6 kΩ,氮气流量200 mL/min,氧气流量180 mL/min,进样速度0.5~0.6μL/s。在此条件下,1~10 mg/L不同浓度的4个氯标准样品的回收率为96%~105%,准确度满足要求。试验分别重复测定6次的相对标准偏差小于5%,可满足轻石脑油中微量氯含量测定的需要。The chlorine content in naphtha was determined by microcoulometry method, and influences of the operating parameters of the microcoulometry analyzer on the test results were investigated. The results showed that the optimum work conditions of the microcoulometry analyzer were as follows: the bias voltage was 250~260 mV, the integral resistance was 6 kΩ, the nitrogen flow was 200 mL/min, the oxygen flow was 180 mL/min, sample injection rate was 0.5~0.6 μL/s. Under the previously mentioned conditions, recovery rate of four standard samples with chlorine content from 1~10 mg/L were 96%~105%, the accuracy met the requirement. The relative standard deviation of the repeated determination for six times was less than 5%, which met test requirement of the determination of trace chlorine in light naphtha.
分 类 号:TE626[石油与天然气工程—油气加工工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.117