作 者:杨芃原[1,2] 李顺祥 贾滨[2] 刘颖超 朱晨鑫 刘凯 赵和玉 YANG Peng-yuan;LI Shun-xiang;JIA Bin;LIU Ying-chao;ZHU Chen-xin;LIU Kai;ZHAO He-yu(Engineering Center of Ministry of Education for Innovation Scientific Instruments,Department of Chemistry,Fudan University,Shanghai 200438,China;Minhang Hospital and Institutes of Biomedical Sciences,Fudan University,Shanghai 201100,China)
机构地区:[1]复旦大学化学系和创新科学仪器教育部工程中心,上海200438 [2]复旦大学附属闵行医院和生物医学研究院,上海201100
出 处:《质谱学报》2020年第1期1-10,I0001,共11页Journal of Chinese Mass Spectrometry Society
基 金:国家蛋白质机器专项项目(2017YFA0505104、2017YFA0505001);国家卫健委专项项目(SQ2017YFSF090210、YS2017YFSF090099)资助
摘 要:飞行时间质量分离器是飞行时间质谱仪的主要组成部分。飞行时间质谱(TOF MS)具有分析质量范围宽、分析速度快、仪器结构简单等优点,但离子初始动能和初始位置容易分散是影响其分辨率的核心因素。本综述根据本课题组多年的研制经验,着重介绍离子束垂直引入方式的反射式有栅网飞行时间质谱的离子光学以及相关电子学控制的核心技术原理。离子光学核心技术涉及到离子加速场和离子反射场的机械加工控制和精密装配控制等,电子学控制核心技术主要包括高压电源和高压脉冲电源的精密制作。Time of flight mass separator is the major component of the quadrupole time of flight mass spectrometry(Q-TOF MS).Time of flight mass spectrometer(TOF MS)measures mass spectra by using the principle that different mass charge ratio ions have different flight times for same distance within a free flight field in vacuum.TOF MS has the advantages of microsecond-level fast detection speed,high ion transmission rate,high sensitivity and precision.Theoretically,there is no upper quality limitation which means large quality detection range.With its resolution increasing and these advantages,TOF MS is now widely used.The core factor affecting TOF MS resolution is that the initial kinetic energy and the initial position of ion are easily dispersed.For mass spectrometers,ion optics and electrode-powered systems form the electric field that controls ions.Vacuum provides the environment needed for operation.Signal detection systems are responsible for the measurement and acquisition of ion signals,while computer software and control systems are key to integrating all parts.This review started with a theoretical calculation of the time of flight mass separator,deduced an ideal formula,and provided a computer optimization to determine the required mechanical and electrical parameters.Based on the development experience in author’s laboratory yearly,the review would focus on the ion optics and related electronic control technique of TOF MS,such as vertical ion beam introduction,grid-connected fields,reflectron,and etc.The ion optical technique involved the precision manufacture,and the assembly of acceleration field and reflection field.The key to the success of a time of flight mass separator was the machining precision.A good optical system should provide the ideal quality resolution.The mechanical position and shape of electrodes of the ion optical system were physically fixed after design.The other boundary condition for controlling the electric field of ion motion depended on the voltage applied to the electrodes.These v
关 键 词:飞行时间质谱(TOF MS) 离子反射器 离子光学 电气控制
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.219.81.99