作 者:Rijo Jackson Tom Suresh Sankaranarayanan Victor Hugo C.de Albuquerque Joel J.P.C.Rodrigues
机构地区:[1]CMR Institute of Technology,Bengaluru 560037,India [2]SRM Institute of Science and Technology,Chennai 603203,India [3]University of Fortaleza(Unifor),Fortaleza,CE 60811-905,Brazil [4]Federal University of Piaui,Teresina-PI,64049-550,Brazil [5]Instituto de Telecomunicacoes,1049-001 Lisboa,Portugal
出 处:《China Communications》2020年第1期104-117,共14页中国通信(英文版)
基 金:National Funding from the FCT- Fundacao Para a Ciencia e a Tecnologia through the UID/ EEA/50008/2019 Project by Brazilian National Council for Scientific and Technological Development via Grant No. 309335/2017-5
摘 要:Advanced Metering Infrastructure(AMI)forms an important part in Smart Grids.Routing the data effectively from smart meters to the Edge/Fog node requires an efficient routing protocol.Routing Protocol for Low Power Lossy Area Network(RPL)is a standard routing protocol for IPv6 over Low Power Personal Area Network(6LoWPAN).In a Power Distribution system all the smart meters together form 6LoWPAN network.They communicate with the fog router,which acts as the 6LoWPAN gateway.ContikiRPL was evaluated using Cooja Network simulator for a power distribution network topology.The nodes which were far away from the fog node gave low Packet Delivery Ratio(PDR)and large End to End delay.This paper proposes an aggregation RPL scheme by modifying the existing Contiki RPL.The smart meter nodes communicate to the aggregator,which communicates to the fog node.The results show that the aggregation scheme has 35.6%increase in PDR,lesser hop count and 13.24%decrease in End to End delay on an average compared to existing RPL.Advanced Metering Infrastructure(AMI) forms an important part in Smart Grids. Routing the data effectively from smart meters to the Edge/Fog node requires an efficient routing protocol. Routing Protocol for Low Power Lossy Area Network(RPL) is a standard routing protocol for IPv6 over Low Power Personal Area Network(6 Lo WPAN). In a Power Distribution system all the smart meters together form 6 Lo WPAN network. They communicate with the fog router, which acts as the 6 Lo WPAN gateway. Contiki RPL was evaluated using Cooja Network simulator for a power distribution network topology. The nodes which were far away from the fog node gave low Packet Delivery Ratio(PDR) and large End to End delay. This paper proposes an aggregation RPL scheme by modifying the existing Contiki RPL. The smart meter nodes communicate to the aggregator, which communicates to the fog node. The results show that the aggregation scheme has 35.6% increase in PDR, lesser hop count and 13.24% decrease in End to End delay on an average compared to existing RPL.
关 键 词:IOT 6LoWPAN RPL ROUTING distribution automation smart grid fog computing