扭曲内肋管的换热与流阻特性分析  被引量:2

Analysis of heat transfer characteristics and flow resistance characteristics of twisted inner fin tube

在线阅读下载全文

作  者:李慧君[1] 闫琪 LI Huijun;YAN Qi(School of Energy Power and Mechanical Engineering,North China Electric Power University,Baoding 071003,China)

机构地区:[1]华北电力大学能源动力与机械工程学院

出  处:《电力科学与工程》2019年第12期61-67,共7页Electric Power Science and Engineering

摘  要:为了减少传热过程中的热阻,实现节能降耗,强化换热是行之有效的措施。采用异型管和肋片相结合的方式以达到强化换热的目的。通过将扭曲管和不连续斜肋相结合,建立了不同肋排数的扭曲内肋管的几何和数学模型;在给定条件下,对模型进行了验证,并进行热力性能的三维数值模拟。结果表明:在相同雷诺数Re下,加肋扭曲管的努赛尔数大于不加肋扭曲管的努赛尔数,且加肋排数越多,努赛尔数Nu越大。相同条件下,带肋的扭曲换热管的阻力系数大于无肋的换热管,加肋排数越多,阻力系数越大。带肋扭曲管的j因子要比没有加肋扭曲管大,但随着流体流速的增加,压损增加,换热性能有所下降;八排肋扭曲管的强化换热因子(j)比不加肋扭曲管提高约9%。由场协同数判定:加肋扭曲管的场协同数优于不加肋扭曲管。因此,所研究的扭曲内肋管性能更优越。Enhancing heat transfer is an effective method to reduce the heat transfer resistance and achieve energy saving in the flow process.The paper combines shaped tubes and fins to achieve the aims of enhancing heat transfer.To this end,the geometric and mathematical models of twisted inner fin tube with different number of tubes are established by the combination of the twisted tube and the discontinuous oblique fin.Under given conditions,the model is verified and the three-dimensional numerical simulation is carried out.The results show that the Nusselt number of the finned twisted tube is larger than that of the non-finned twisted tube at the same Reynolds number,and the more finned rows are,the larger the Nusselt number is.The resistance coefficient of the twisted tube is larger than that of the finless heat exchange tube at the same conditions,and the more finned rows are,the larger the resistance coefficient is.The heat transfer enhancement factor(j)of the finned twisted tube is larger than that of the twisted tube without the fin.However,the pressure loss increases and the heat transfer performance decreases as the fluid flow rate increases.The heat transfer enhancement factor(j)of the eight rows of finned twisted tubes is about 9%higher than that without fins.To the extent,the number of field synergies of the finned twisted tubes is superior to that of the un-finned twisted tubes.Therefore,the performance of the twisted inner fin tube is superior.

关 键 词:扭曲内肋管 斜肋 换热性能 流阻性能 数值模拟 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象