电站锅炉喷水减温器典型失效分析  被引量:5

Typical Failure Analysis of Water Spray Desuperheater in Power Plant Boiler

在线阅读下载全文

作  者:张立新 ZHANG Lixin(CHN Energy Heze Power Generation Co.,Ltd.,Heze 274032,China)

机构地区:[1]国家能源菏泽发电有限公司

出  处:《山东电力技术》2020年第2期70-76,共7页Shandong Electric Power

摘  要:喷水减温器的运行情况是影响电站锅炉安全经济性的主要因素之一。结合420 t/h锅炉再热器微量喷水减温器及连接管弯头、高温再热器入口联箱与1025 t/h锅炉再热器微量喷水减温器连接管弯头、过热器三级减温器本体及管座角焊缝等失效案例,依据断裂力学原理,采用宏观检查、金属检验、应力分析等手段揭示部件失效的原因,为此类承压部件的监督检验及运行维护提供参考依据。The operation of spray desuperheater is one of the main factors affecting the safe and economic operation of utility boilers.Based on fracture mechanics principle,the visual inspection,metal inspection and stress analysis are adopted for analyzing the failure cases of 420 t/h boiler reheater micro spray desuperheater and connecting pipe,elbow,high temperature reheater inlet header and 1025 t/h boiler reheater micro spray desuperheater connecting pipe elbow,superheater stage 3 desuperheater body and fillet weld of tube base.In this paper,a reference basis is provided for supervision,inspection and operation and maintenance of such pressure components.

关 键 词:喷水减温器 裂纹 应力集中 机械疲劳 热疲劳 调峰机组 

分 类 号:TK229[动力工程及工程热物理—动力机械及工程]

 