检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:尚东方 刘敦龙 韩雪 王瑞玺 SHANG Dong-fang;LIU Dun-long;HAN Xue;WANG Rui-xi(Tianjin Research Institute for Water Transport Engineering,Ministry of Transport,Tianjin 300456,China;College of Software Engineering,Chengdu University of Information and Technology,Chengdu 610225,China;Sichuan Province Key Laboratory of Automatic Software Generation and Intelligence Service,Chengdu 610225,China)
机构地区:[1]交通运输部天津水运工程科学研究所,天津300456 [2]成都信息工程大学软件工程学院,四川成都610225 [3]软件自动生成与智能服务四川省重点实验室,四川成都610225
出 处:《计算机与现代化》2020年第3期6-12,18,共8页Computer and Modernization
基 金:中央级公益性科研院所基本科研业务费专项(TKS170209);四川省科技厅应用基础项目(2018JY0456);四川省教育厅科研项目(18ZA0091)。
摘 要:目前的泥石流次声报警设备经常受环境噪声干扰而频繁产生误报,导致无法投入到实际应用中。为了提高泥石流次声监测预警的准确率,基于泥石流次声和环境干扰次声的特征差异这一原理,采用单片机与上位机相结合的方式,借助混合编程、数据库与GIS二次开发等技术手段,设计与开发基于次声监测的泥石流实时预警系统进行现场泥石流次声信号监测与判识。对云南东川蒋家沟长期现场泥石流的监测验证了该系统的工作性能。实际应用结果表明:该系统不仅具有操作简便、响应及时和实时识别等特点,还具有较高的预警准确率,在长达2年的野外监测过程中,仅出现18次误报且无一漏报。False alarm often arises from the current debris flow infrasound alarms under the environmental noise interference;therefore,it cannot be put into practical application.To improve the accuracy of debris flow infrasound monitoring and warning,based on the principle of characteristics difference of infrasound signals generated from debris flow and environmental interference,combining microcontroller with upper computer,an efficient and reliable real-time debris flow early-warning system based on infrasonic monitoring is designed and realized by means of hybrid programming,database and secondary development of GIS,etc.The recognition performance of the system has been verified by long-term in-situ monitoring of debris flows in Jiangjia Gully,Dongchuan,China.The verified results show that the system not only has the characteristics of stable operation,timely response and real-time recognition,but also has high warning accuracy and low false alarm rate,during two years of field monitoring,there were only 18 false positives and none was missed.
分 类 号:TP274[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.12.111.193